48
10.4.10 Inverter compressor drive error diagnosis and solution(P4)
Error Code
P4
Malfunction decision
conditions
An abnormal inverter compressor drive is detected by a special
detection circuit, including communication signal detection,
voltage detection, compressor rotation speed signal detection
and so on.
Supposed causes
Wiring mistake; IPM malfunction;
Outdoor fan ass’y faulty
Compressor malfunction; Outdoor PCB faulty
Trouble shooting:
Check if the wiring between main
PCB and compressor connected by
error and if the wires and connectors
are broken?
Correct the connection or replace
the wires and connectors.
Yes
No
IPM continuity check. Check if the
IPM terminal resistance values are
uniform. Refer to page 64.
Replace the IPM board or replace the
main PCB if the IPM board and main
PCB are integrated together.
No
Check if the outdoor fan runs
properly or the outdoor unit
ventilation is good.
Yes
No
please refer to the below remark, check whether the
resistance of the fan motor is normal. If not, replace
the fan motor.
Yes
Check if the compressor resistance
values are uniform .Refer to page 63.
No
Replace the compressor.
Yes
Replace the outdoor main PCB if the
main PCB and IPM are separate.
6)
BIN625C2V32-IW and MS11D-22HRDN1-MN10W models: Measure the black pin and red pin of the motor
connector, the resistance should be around 88.5
Ω
at 20
℃
(68
℉
)
Summary of Contents for PIN413C2V31
Page 7: ...5 2 2 Part names of Indoor Outdoor units ...
Page 14: ...12 6 Wiring Diagram 6 1 Indoor Unit PIN413C2V31 I PIN519C2V31 I ...
Page 15: ...13 PIN624C2V31 IW ...
Page 16: ...14 6 2 Outdoor Unit PIN413C2V31 O PIN519C2V31 O ...
Page 17: ...15 PIN624C2V31 O For PIN413C2V31 O ...
Page 18: ...16 For PIN519C2V31 O For PIN624C2V31 O ...
Page 46: ...44 P U P V ...
Page 47: ...45 P W P N ...