Page 154
VoIP gateway IP400 version 5.01
Option
Description
How to code
POSIX TZ
Defines the time
zone and the date of
the change for day-
light saving (Sum-
mer time).
Enter the correct TZ string
into the field, as you would
enter it in the equipment's
configuration applet. See sec-
tion 8.1.3 “Defining the
source for time and date”
from page 110.
VLAN ID
The 802.1q VLAN ID
for the data to be
sent and received
from your equip-
ment.
Enter the numerical ID into
the 16 bit field.
VLAN Priority
The 802.1p VLAP
priority for data sent
from your equip-
ment.
Enter the numerical priority
into the 8 bit field.
TOS Bits
The value of the IP
TOS field in the IP
header of voice data
sent from the equip-
ment.
Enter the numerical priority
into the field. Add the prefix
0x
when entering hexadeci-
mal numbers, or start with the
prefix
0
, to specify octal num-
bers.
Enbloc dialling
The number of sec-
onds, that the
dialled digits will be
kept in the IP 200,
before they are sent
“en bloc” to the
gatekeeper.
Enter the number of seconds
into the 8 bit field.
The value
0
means that en
bloc dialling is deactivated
and the dialled digits will be
immediately transmitted to
the gatekeeper.