VoIP gateway IP400 version 5.01
Page 23
dentally interrupted. If you decline the restart (
Later
button), you can enforce it
later on, by clicking on the
Reset
or
Reset when idle
button.
Reset
is used for an immediate restart, whereas
Reset when idle
only restarts
if there are no active calls. This prevents existing calls from being disconnected
by a restart.
The gateway might no longer be accessible, after activating the new configura-
tion, if it was not performed properly. This would be the case, for example, if an
Ethernet interface parameter such as an IP address or subnet mask is set incor-
rectly. In such a case, it would no longer be possible to fix the mistake using the
configuration user interface.
If no access is made either from the configuration user interface or from
Telnet
within 60 seconds, the gateway will thus discard the activated configuration and
restore the configuration held in the non-volatile memory. If
Save
,
Activate
or
Reset
is actuated, the configuration applet automatically reconnects to the gate-
way, with the effect that the new configuration is automatically saved, if success-
ful.
You can cancel all changes made since the last
Save
by using the
Cancel
button.
The current configuration will then be replaced by the last configuration saved in
the non-volatile memory.
Caution
Please bear in mind, that it's not possible to restore a useable configuration if
a problem occurs after a
Save
. For remote maintenance in particular, under
certain circumstances, access to the device may be no longer possible. We
thus strongly recommended that you first check any changes to the configu-
ration, using
Activate
.