User Manual: 10 Gallon Smart Foam Unit | English

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

 Model No.: FI-10N-SM, FI-10NK-SM, FI-10NV-SM AND RELATED UNITS

Operation Instructions:

1.  Verify that the drain plug (DP-A) is securely closed.
2.  Follow all instructions from the chemical manufacturer.  

Fill the tank with water and the advised percentage of 

chemical concentrate.

3.  Verify that the valve (PVCV34FM) at the base of the 

suction line is open, to allow fluid into the suction line.

4.  Verify that the air trigger port is clean and free of 

blockages or debris, and the discharge hose is not kinked 

or obstructed.

5.  With the wand pointed in a safe direction, connect an air 

line to the air inlet fitting (AP25).  

Note: When you connect the air line, listen for any sound 

from the unit. If you hear the pump activate and begin to 

cycle, disconnect the air line immediately. This indicates 

that there is a blockage or other problem somewhere 

in the system, which could cause the unit to activate 

spontaneously. The problem must be addressed before 

proceeding (see “Troubleshooting Instructions”).

6.  Place thumb over the air trigger to activate the unit and 

begin foaming.

7.  While the unit is running and discharging product, adjust 

the needle valve (NV14Y) as needed to regulate the 

wetness or dryness of the foam following the steps below:

a.  Close needle valve completely in clockwise direction.

b.  Open needle valve in counter-clockwise direction 2 

complete turns.

c.  Continue to open needle valve in ¼ turn increments, 

allowing 30 seconds between adjustments, until 

desired consistency of foam is achieved.

8.  Release the air trigger to stop foaming. 

Note: When you release the air trigger, the unit will shut 

off and depressurize. Foam that is already in the discharge 

hose may seep out, but no more foam will be created 

until you cover the air trigger again.

After Use Instructions: 

1.  Open the drain plug (DP-A) and drain the unit tank.
2.  Rinse the unit tank thoroughly with fresh water. Then 

replace the drain plug and fill the tank with fresh water.

3.  Activate the unit and allow it to run for 2-4 minutes, or 

until all chemical has been flushed from the system.

4.  Open the drain plug (DP-A) and drain any water remaining 

in the unit tank. Then replace and secure the drain plug.

5.  Disconnect the air line from the air fitting (AP25).
6.  Allow any liquid remaining in the discharge hose to drain 

out through the discharge wand before storing the unit.

Maintenance Instructions:

To keep your unit operating properly, periodically perform the 

following maintenance procedures:

Note: Before performing any maintenance, ensure that the

unit has been disconnected from the air supply according to the

“After Use Instructions.” Also ensure that the unit tank is empty,

and/or close the valve (PVCV34FM) at the base of the suction

line to shut off the flow of liquid from the tank. Reopen the

valve after maintenance is complete.

•  Inspect the air pump (P56/P56K/P56V) for wear and leaks.
•  Inspect all hoses for leaks or excessive wear.  Make 

sure all hose clamps are in good condition and properly 

secured.

•  Check the air trigger port on the handle for debris and 

clean as needed. When cleaning, be careful not to push 

debris into the port, as it may become lodged inside and 

create a blockage.

•  Clean and replace the filter (AFR25) located within 

the air regulator (R25) as needed. Access the filter by 

unthreading the air regulator bowl (ABR25) from the air 

regulator (R25).

•  Check the suction line and strainer (STR38-IL) for debris or 

blockages, and clean as needed.

•  Drain your air compressor tank on a regular basis to help 

extend pump life. An air source with a high moisture 

content will accelerate pump wear. Note: If your air 

source has a high moisture content, you may wish to 

install a water separator (WS-20CFM) before the unit.

Summary of Contents for FI-10N-SM

Page 1: ...USER MANUAL MODEL NUMBER FI 10N SM FI 10NK SM FI 10NV SM AND RELATED UNITS 10 Gallon Smart Foam Unit English Original Instructions...

Page 2: ...ways keep the discharge hose free of kinks or obstructions Always rinse and drain unit after use as described in the After Use Instructions Always store unit disconnected from the compressed air sourc...

Page 3: ...e Compressed air Chemical pickup type Draws from pre mixed solution Number of products unit can draw from One product Capacity 12 5 gallons 47 3 liters Discharge hose diameter length 20 ft 9 1 m bonde...

Page 4: ...foam will be created until you cover the air trigger again After Use Instructions 1 Open the drain plug DP A and drain the unit tank 2 Rinse the unit tank thoroughly with fresh water Then replace the...

Page 5: ...e pressure by turning the knob on the top of the air regulator R25 3 If the problem persists the stainless steel mixing mesh SS MESH inside the tee fitting SST12HB38 could be plugged Remove and clean...

Page 6: ...IPMENT Model No FI 10N SM FI 10NK SM FI 10NV SM AND RELATED UNITS SSP12 SSAXLE14 AS1 VS W15 FWAX15 PVCV34FM COT TANK 10N DFP7 DP A TANK ASSEMBLY ITEM NUMBER TANK 10N A SSC58 SSC14 HBSS1258 HBSS1814 SM...

Page 7: ...SM AND RELATED UNITS H38B H SST12HB38 SSC38 P56 P56K or P56V P56 BRKT P56 BRKT SCREW NV14Y AG100 R25 BPS 58SO BPS SSR SN1414 HBSSEL1438 P18 HBSSEL1438 H14B H CV38 Available per Available per HBBEL141...

Page 8: ...SC1212 HBSS1258 EC58 HBSS1258 EC58 H58 6 ITEM NUMBER EC58 OETIKER CLAMP 0 625 ID H58 6 6 FT OF 5 8 INCH BLUE HOSE HBSS1258 STAINLESS STEEL HOSE BARB 1 2 MPT BY 5 8 INCH BARB SC1212 S S COUPLER 1 2in...

Page 9: ...8 HOSE BARB HHPB3414 HEX HEAD POLY REDUCER BUSHING 3 4 X 1 4 NV14Y FLOW CONTROL VALVE INCLUDES BLACK KNOB NV14Y HNDL BLACK KNOB FOR NEEDLE VALVE 2839 1 4 P18 PLUG 1 8 MPT HEX HEAD 304 SS P56 PUMP WITH...

Reviews: