1
Document Name : OIM V 1.0 Page 1 of 7
i
INSTALLATION GUIDELINES
1. Prepare the cut-out with proper dimension as shown in figure.
2. Remove clamp from Controller.
3. Push the Timer through panel cut-out and secure the
Controller in its place by tightening the side clamp.
SPECIFICATIONS :
Display
: Dual 4
Status Indication
: a
]
Relay status (OP1/OP2)
b] Auto Reset / EOC Time (RT)
c] Time Unit (Hrs. / Min. / Sec.)
Control Inputs
: a] Count Input (For Counter)
b] Start Input (For Timer)
b] Reset Input
Reset time
: < 100 ms
Timing Accuracy
: 0.05% Full Scale
Repeat Accuracy
: 0.01%
Outputs
: 5 Amp @ 230VAC Relay (1C/O) x 2
Reset
: a] Front switch (Programmable)
b] Remote Reset (via rear terminals)
C] At On power (Programmable)
Supply
: 90 to 270 VAC
Mounting
: Panel
Housing
: ABS Plastic
o
Operating temp.
: 0 ~ 50 C
Humidity
: 95% Rh (Non Condensing).
Configurable Parameters:
Mode
: a] Counter
b] Timer
Counter Parameters :
Count Input
: AC / DC
Count Frequency
: Various selectable frequencies
(For DC Input only)
Count direction
: Up / Down
Function
: On Delay / Off Delay
Timer Parameters :
Count direction
: Up / Down
Timer Start
: Various selectable start mode
Timer Function
: a] ON / OFF delay b] Cyclic mode
Output 2 Function
: a] Auxiliary
b] End of Cycle (EOC)
c] Off
d] Invert
Digit 7-segment LED,
SAFETY INSTRUCTION
MECHANICAL
v
Ambient temperature and relative humidity surrounding the
Controller must not exceed the maximum specified limits.
v
The Controller in its installed state must be protected against
excessive electrostatic or electromagnetic interferences.
ELECTRICAL
v
The Controller must be wired as per wiring diagram & it must
comply with local electrical regulation.
v
The Electrical noise generated by switching inductive loads
might create momentary Fluctuation in display, latch up, data
loss or permanent damage to the instrument. To reduce this use
snubber circuit across the load.
B
D
A
G
F
PANEL
CUTOUT
E
C
OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)
+12V
PNP
NPN
GND
RST
+12V
PNP
NPN
GND
RST
Contact Switch
Proximity (NPN)
Proximity (PNP)
Wiring For Count Input & Remote Start
PNP
+12V
RST
GND
NPN
1
2
RST
+12 V
PNP
NPN
GND
HLD
7
8
11
10
9
12
4
3
5
6
KTC-44
SUPPL
Y
L
N
NO 1
CM 1
+
-
NO 2
CM 2
+
-
TERMINAL CONNECTIONS :
OP
1
OP
2
5
4
3
RST
+12 V
PNP
NPN
GND
HLD
KTC - 77
1
2
8
7
6
SUPPL
Y
L
N
9
10
13
12
11
14
15
16
-
NO 2
CM 2
NC 2
+
-
NO 1
CM 1
NC 1
+
OP 1
OP 2
22
21
20
19
18
17
RST
+12 V
PNP
NPN
GND
HLD
KTC-99
SUPPL
Y
L
N
1
2
4
3
5
16
15
12
13
14
8
7
6
10
9
11
-
NO 1
CM 1
NC 1
+
-
NO 2
CM 2
NC 2
+
OP 2
OP 1
Model
Dim
96
72
48
96
72
48
14
14
14
80
80
86
92
68
44
92
68
44
KTC - 99
KTC - 77
KTC - 44
A
B
C
D
F
G
E
90
70
44
Display height (SV)
Display height (PV)
Model no.
0.36”
KTC-44
0.36”
KTC-77
0.39”
0.56”
KTC-99
0.80”
0.56”
White
Green
Display Colour
USER’S OPERATING MANUAL FOR DIGITAL PRESET TIMER COUNTER
(Models: KTC - 44 / 77 / 99)
KTC - 99
(96 X 96)
(72 X 72)
KTC - 77
KTC - 44
(48 X 48)