6
Document Name : OIM V 1.0 Page 6 of 7
Lower
Display
Description
Default
Parameter
Upper
Display
Continue
Repeat
Cycle
Total Time:-
The cycle will be executed for the total time fed in the TOT parameter in
the user list.
Number of Cycle:-
The cycle will be executed for the value fed in nC parameter in
the user list.
Continue :-
The cycle will be continuously executed till a reset pulse is given either
from rear terminal or front reset.
Repeat Cycle :- This parameter will be prompted only when the timer function is
selected as CY1, CY2 or CY3.
Hold
Start
Cycle 3
from
Forward:-
Starts the operation from Forward time.
Hold :-
Starts the operation from Hold time.
Start Cycle 3 from :-
This parameter will be prompted only when the timer function
is selected as CY3.
Front
Reset
Enable
Front Reset :-
function. This feature prevents un-authorized attempt to Reset the Timer during
Run mode.
This parameter allows the user to Enable or Disable front Reset
Disable :-
The Timer can not be reset through front panel.
Enable :-
The Timer can be reset through front panel.
Gate
Input
Disable
Gate Input :-
(Set to yes) the External Input can work as a Gate input.
Prompted only if Timer is configured as Power On Start. When Enabled
Disable :-
The External Input can not be used as a Gate input.
Enable :-
The External Input can be used as a Gate input.
i
Disable
Memory
Backup
Memory Backup :-
This parameter allows the user to Enable or Disable memory
backup function.
Enable :-
Memory backup for run time value.
Disable :-
No memory backup for run time value.
Auxiliary
Output 2
Function
End of Cycle Output :-
The OP2 is energized for EOC period programmed by user
via EOC time in User list in Seconds only.
2-Fn parameter will NOT be prompted in CY3 mode.
OFF:-
If selected , OP2 will completely OFF.
AUXILIARY:-
If selected , OP2 can be used as Auxiliary contact. Both the relay
output will ON/OFF together as per the ON/OFF Delay.
INVERT:-
If selected , OP2 logic will be inverse of OP1. Both the relay output will
ON/OFF vice-versa as per the timer function.
Disable
StartUp
Delay
Startup Delay :-
This time will always be executed if ENABLED before the start of
every timing cycle. The outputs will remain OFF during this time.
Enable :- This will enable the startup delay.
Disable :- This will disable the startup delay.
10.0
Startup
Delay
Time
Startup Delay Time :- Range: 0.1 to 999.9 seconds
Startup Delay Time :-
This parameter is prompted only when the Startup Delay Time
is ENABLED
USER LIST : To access the user list press & release SET key once.
Range
Lower
Display
Description
Default
Parameter
Upper
Display
0.01 - 999.9
10.0
SET TIME 1 : Set time for On delay & Off delay modes.
SET TIME 1
0.01 - 999.9
5.0
EOC TIME : OP2 function is set to EOC. This parameter sets the End of
cycle time ( Fixed in seconds)
EOC
TIME
a) For On & Off Delay Mode: