User Manual
–
NV200 Spectral
Copyright © Innovative Technology Ltd 2019
Doc: User Manual NV200 Spectral
Version: 2.1
Page 50 of
95
6.4.3.2
NV200 Spectral and Smart Coin System
Part Name
Description
Quantity
NV200 Spectral
NV200 Spectral Note Validator
1
IF17
USB Interface Converter /
1
CN397
Docking Plate / Spectral Payout to Host Cable
1
CN214
USB A to B Cable Assembly
1
Power Requirements
This setup option requires a stable 24VDC / 3.5A power supply for the NV200
Spectral whilst the SCS requires 24V DC 7.5A according to the product specification.
Check the power requirements of your host machine and other peripherals to
dimension a proper power environment for your system setup.
Caution
It is very important that the cashbox chassis of the NV200 Spectral is bonded to
earth, as lack of proper bonding can cause communication issues and failures. The
earth bonds on a NV200 Spectral should be made to the intended connection on the
outer Cashbox. The resistance between the cashbox and the Earth pin on the mains
plug should be less than 0.7 ohms.