User Manual
–
NV200 Spectral
Copyright © Innovative Technology Ltd 2019
Doc: User Manual NV200 Spectral
Version: 2.1
Page 49 of
95
6.4.3
Setup Examples
The drawings below highlight how to connect the NV200 Spectral to an SSP host
machine using available cables and interfaces from Innovative Technology Ltd. For
cable drawings refer to
Appendix 11.1
.
6.4.3.1
NV200 Spectral
Drawing 1 - NV200 Spectral USB connection
Part Name
Description
Quantity
NV200 Spectral
NV200 Spectral Note Validator
1
IF17
USB Interface Converter /
1
CN397
Docking Plate / Spectral Payout to Host Cable
1
CN214
USB A to B Cable Assembly
1
Table 1 - ITL Part Numbers
Power Requirements
This setup option requires a stable 24VDC / 3.5A power supply for the NV200
Spectral according to the product specification.
Check the power requirements of your host machine and other peripherals to
dimension a proper power environment for your system setup.
Caution
It is very important that the cashbox chassis of the NV200 Spectral is bonded to
earth, as lack of proper bonding can cause communication issues and failures. The
earth bond on a NV200 Spectral should be made to the intended connection on the
outer Cashbox. The resistance between the cashbox and the Earth pin on the mains
plug should be less than 0.7 ohms.