User Manual
–
NV200 Spectral
Copyright © Innovative Technology Ltd 2019
Doc: User Manual NV200 Spectral
Version: 2.1
Page 54 of
95
To open the note path cover, pull the top cover release latch forward (towards the
bezel) and lift the cover as shown below (it is recommended to also remove the
bezel to allow correct cleaning of the note path guides):
The note path is visible and can be cleaned. Carefully wipe the surfaces with a soft
lint free cloth that has been dampened (NOT wet) with a water and mild detergent
solution (e.g. household washing up liquid) - be very careful when cleaning around
the sensor lenses and make sure they are clean and dry before closing the cover and
powering the unit.
Caution!
Do not use any lubricants.
Do not lubricate any of the note transport
mechanism or any part of the note path, as this
can affect the operation of the validator.
WARNING!
Do not try to disassemble
Do not attempt to disassemble the validator
head
–
trying to do this could cause personal
injury and will damage the unit beyond
repair.
7.3.2
Cleaning the TEBS Cashbox
Remove the cashbox as this provides access to the moving parts within the TEBS
cashbox. Once the cashbox has been removed, detach the NV200 Spectral head this
provides access to the drive gears.
Manually turn the stacker drive this will move the stacker forward, when at the full
extension there is a tactile bump. This will hold the stacker out allowing compressed
air (Max pressure = 5 bar) to be blown into the unit.
Cover
release
latch
Note path guides