Belt Cleaning – Every 2 Months (Or As Required)
1.
Ensure the validator is enabled (i.e. Bezel lights are illuminated)
2.
Remove Bezel.
3.
Insert a piece of paper, which is narrower than the width
between
the two belts, in the centre of the note path to activate the
drive motor.
4.
Use a lint free cloth dampened with water containing a mild
detergent such as dish detergent and hold it against each
drive belt as is turns.
5.
Repeat steps 3 and 4 until all dust and debris has been
removed from both belts.
6.
Repeat step 3 using a DRY lint free cloth to remove any
excess moisture.
Note Path Debris Clearing / Belt Changing – When required
To access the note path and lozenge, slide the red release catch on the end of the NV9USB
Validator and lift to open. Push the lozenge release catch and lift; the note path and lozenge
are now exposed for maintenance (see picture).
Debris Clearing
Examine the note paths, lozenge and note
stacker for any dirt or debris.
Carefully clear and wipe the surfaces of the note
paths and lozenge with a soft lint free cloth that
has been dampened with a water and mild
detergent solution (i.e. household washing up
liquid.). Take particular care around all the
sensor lenses (see picture), ensuring they are
clean and dry.
Check that the note stacker and cash box spring
plate are not jammed.
Belt Changing
Remove and place the lozenge on a clean dry surface and remove
the belts, sliding them off the smallest wheels first. This will be
easier if pressure is applied to the larger wheels at the front. Replace
the belts using the reverse procedure from the above.