background image

 

Smart Coin System User Manual   

Page 

19

 of 

28

 

   

 

 

Copyright © Innovative Technology Ltd 2015 

GA02033 

5.2

 

Technical Specifications 

 

Power Requirements  

Performance & Reliability 

Recommended 
Voltage 

24V 

Weight 

Empty 

Full 

  

4kg 

18kg (approx) 

Minimum 
Voltage 

21.6V 

MCBF (cycle) 

150,000

[1]

 

Maximum 
Voltage 

26.4V 

MCBI (cycles) 

50,000

[1]

 

Standby Supply 
Current 

200mA 

Acceptance

[4]

 

95% 

Running Supply 
Current 

3A 

Acceptance (3rd 

time)

[4]

 

97.00% 

Peak Supply 
Current 

6.5A 

Duty Cycle 

  

Recommended 

PSU 

7A 

Cycle Time 

  

Warranty  

12 Months 

Maintainable Life 

1,000,000 cycles 

  

 

 

 

 

 

 

 

 

  

Media Specifications 

  

Min 

Max 

Capacity  

1500 x €1

 

Diameter 

18mm 

28.5mm 

  

 

  

1200 x £1 

Thickness 

1.65mm 

3.2mm 

  

  

     

  

  

 

 

 

 

 

 

 

 

  

Environmental Specifications 

Supported Interfaces 

Maximum 

Temperature 

+ 50°C 

(e)SSP over ~TTL, cctalk (CC2) 

Minimum 

Temperature 

+ 3°C 

~TTL levels:  

Maximum 

Humidity 

95% NC 

Inputs: 0.5V max = 0, 3.7V min = High 
internal pullup 

Minimum 

Humidity 

5% 

Outputs: o/collector 0.6V min = Low 
Max current sink 50mA 

  

 

 

 

 

 

 

 

 

  

Preventative 
Maintenance 
Schedule: 

- Every 10,000 cycles check belt to ensure it is in good condition. Clean 
optical level switch on the inside. 
- Every 50,000 cycles clean coin dust. 

  

 

 

 

 

 

 

 

 

  

Standards & 
Approvals: 

 IEC 61249-2-21 Materials for PCBs. 

[2]

 

CE/RoHS/WEEE 
IEC/UL 60950 Safety (CB Scheme) 

Notes: 

 

 

 

 

 

 

 

 

 

[1]  To be confirmed by testing 

 

 

 

 

 

[2]  In progress - not yet certified 

 

 

 

 

 

[3]  Street grade true notes (GBP) 

 

 

 

 

 

Please ensure suitable cable is used for power and communication 
connections.

 

 

Summary of Contents for Smart Coin System

Page 1: ...Smart Coin System User Manual Page 0 of 28 Copyright Innovative Technology Ltd 2015 GA02033 Smart Coin System User Manual...

Page 2: ...3 Mounting the Smart Coin System 7 3 4 Connect the unit 8 3 5 Configuration 8 3 5 1 Configuration Button Functions 8 3 5 2 Flash Counts Interface Type 9 3 5 3 DES Trusted Mode 9 3 5 4 Programming and...

Page 3: ...l set If the product proves defective within the applicable warranty period Innovative Technology Ltd will repair or replace the product Innovative Technology Ltd shall have the sole discretion whethe...

Page 4: ...is Caution Mains voltage is present on these terminals This manual set and the information it contains is only applicable to the model stated on the front cover and must not be used with any other mak...

Page 5: ...ple hoppers With a market leading coin hopper capacity and fully audited efficient refills the SMART Coin System is designed to eliminate coin starvation and significantly reduce operator collection c...

Page 6: ...ed coin exit sensor 128 bit AES Encrypted SSP communications eSSP locking option The SMART Hopper can be used to control a coin acceptor making machine wiring and software implementation simpler There...

Page 7: ...ur Smart Coin System already mounted on the baseplate remove it 3 2 Baseplate Mounting Requirements Ensure that the mounting position and note exit hole meets the dimensional requirements as shown bel...

Page 8: ...e to allow the coins to fall clear of the coin exit Secure the baseplate in position using the screw holes provided WARNING Ensure baseplate mounting screws are flush with the surface of the baseplate...

Page 9: ...ion Button on the front of the SMART Coin System body below left of the Led cluster There are several functions available when using the Configuration Button and these are listed in the next table WAR...

Page 10: ...l automatically enter DES trusted mode for 2min to allow for pairing to the host The easiest way to set all levels to zero is to run an empty cycle 3 5 4 Programming and Dataset loading For programmin...

Page 11: ...ing Diode LED indicators that are used to show the status of the unit one Red one Green these can be found on the front of the unit If the SMART Hopper unit is operating normally only the Green LED sh...

Page 12: ...erformance variations over time This has been achieved by careful hardware and software design this attention to the design means there is very little user maintenance required 4 1 Detaching SMART Coi...

Page 13: ...3 4 2 Clearing a Jam from the Hopper 1 Power off the SCS and remove 24volt 4 way power cable 2 Remove the hopper from the mounting plate 3 Empty all coins from the coin bowl 4 Clear the jammed coin fr...

Page 14: ...nology Ltd 2015 GA02033 5 Remove coin cover fraud cover 6 Re move the front panel From the top pull down and right twist and the panel clips off 7 Once the cover is removed check the pistol is not sti...

Page 15: ...28 Copyright Innovative Technology Ltd 2015 GA02033 Clean Sensor and pistol 8 Re fit all parts 9 Re attach the hopper to the mounting base plate and the feeder 10 Re fill the hopper and apply levels...

Page 16: ...catch on the front of the feeder and lift the lid back 3 Clear the jammed coin from the disk and ensure it is free to rotate 4 Wipe the track of any coin dust 5 Ensure the diverter flap is able to mo...

Page 17: ...inding Flash Codes The Smart Hopper module has inbuilt fault detection If there is a configuration or other error the Smart Hopper module LED s well indicates will flash in a particular sequence The S...

Page 18: ...3 Flashes No Encryption key set Host system to negotiate key Red 4 Flashes Coin jammed Remove power manually empty coins from bowl and check hopper base for stuck coins Try manually turning the disc...

Page 19: ...Smart Coin System User Manual Page 18 of 28 Copyright Innovative Technology Ltd 2015 GA02033 5 MECHANICAL ELECTRICAL DOCUMENTATION 5 1 Dimensions...

Page 20: ...eter 18mm 28 5mm 1200 x 1 Thickness 1 65mm 3 2mm Environmental Specifications Supported Interfaces Maximum Temperature 50 C e SSP over TTL cctalk CC2 Minimum Temperature 3 C TTL levels Maximum Humidit...

Page 21: ...rmation Earth resistance The resistance between the base plate and the Earth pin on the mains plug should be less than 0 7 ohms 5 4 Electrical Interfaces SMART Hopper All the connectors needed to set...

Page 22: ...tions The USB connector is a standard Type B USB socket The USB socket can be used for programming the SMART Hopper unit and also bench testing a USB 2 0 compliant Type A to B lead can be used to do t...

Page 23: ...sembly AV Average AWG American Wire Gauge AWP Amusement With Prizes BNV Bank Note Validator ccTalk Coin Controls Talk COMMS Communications CRC Cyclic Redundancy Check DC Direct Current DIA Diameter DI...

Page 24: ...nd MOD Modified or Modification NV Note Validator PCB Printed Circuit Board PDF Portable Document Format PiPS Pay in Pay out System PROM Programmable Read Only Memory PSU Power Supply Unit QTY Quantit...

Page 25: ...m User Manual Page 24 of 28 Copyright Innovative Technology Ltd 2015 GA02033 TTL Transistor Transistor Logic Tx Transmit USB Universal Serial Bus V Volt V_In Voltage In WEEE Waste Electrical and Elect...

Page 26: ...Smart Coin System User Manual Page 25 of 28 Copyright Innovative Technology Ltd 2015 GA02033 7 CABLE DRAWINGS...

Page 27: ...Smart Coin System User Manual Page 26 of 28 Copyright Innovative Technology Ltd 2015 GA02033...

Page 28: ...Smart Coin System User Manual Page 27 of 28 Copyright Innovative Technology Ltd 2015 GA02033...

Page 29: ...2090 E mail support innovative technology co uk Web site www innovative technology co uk BRAZIL suporte bellis technology com br CHINA support innovative technology co uk GERMANY supportDE innovative...

Reviews:

Related manuals for Smart Coin System