NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
10
WIRING DIAGRAM - 240 VOLT
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance
on the left side.
CAUTION: LAbEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN-
GEROUS APPLIANCE OPERATION.
WIRING - 240 VOLT
Figure 21
Figure 22
HOME POWER SUPPLy
240 VAC
120 V (L1) + 120 V (L2) = 240 V
FIREPLACE WIRE
HARNESS
HOME POWER
SUPPLy
240 VAC
120 VAC
120 VAC
WHITE
bLACK
ORANGE
bLUE
bLUE
yELLOW AND GREEN
GROUND
N
L1
L2
240 V 3000 W
GROUND
N
L1
L2
N1
N2
See Power Supply Specifications on
Page 3.
WARNING
Do not install or operate this fireplace through a switch wired in the 120 VAC or 240 VAC circuits. The only approved
wiring for a switch is through the low voltage circuit (24 VAC) as shown on
Page 13
.
L1 = BLACK (POWER)
L2 = ORANGE (POWER)
G = GREEN (GROUND)
N = WHITE (COMMON)
N1 = BLUE (COMMON)
N2 = BLUE (COMMON)
THE 120 VOLT POWER CORD INSTALLED ON
THIS APPLIANCE MUST bE REMOVED (SEE
INSTRUCTION #2 ON PAGE 5).
G