NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
9
WIRING DIAGRAM - 120 VOLT
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance
on the left side.
CAUTION: LAbEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DAN-
GEROUS APPLIANCE OPERATION.
WARNING
Do not install or operate this fireplace through a switch wired in the 120 VAC or 240 VAC circuits. The only approved
wiring for a switch is through the low voltage circuit (24 VAC) as shown on
Page 13
.
HOME POWER -
SUPPLy 120 VAC
FIREPLACE WIRE
HARNESS
See Power Supply Specifications on
Page 3.
N
L1
GROUND
yELLOW AND GREEN
ORANGE
bLACK
bLUE
bLUE
WHITE
N
L1
N1
N2
L2
120 V 1600 W
120 V AC
GROUND
G
IF THE APPLIANCE IS TO bE HARD WIRED
IN, THE POWER CORD MUST bE REMOVED
(SEE INSTRUCTION #2 ON PAGE 5).
Figure 20
WIRING - 120 VOLT
Figure 19
L1 = BLACK (POWER)
L2 = ORANGE (POWER)
G = GREEN (GROUND)
N = WHITE (COMMON)
N1 = BLUE (COMMON)
N2 = BLUE (COMMON)
HOME POWER
SUPPLy
120 VAC