Copyright Innovative Technology Ltd 2008 GA620-1
1
2
16
15
4.3.5 PULSE
In Pulse mode the NV200 outputs a number of pulses on Vend 1. The number of pulses for
each channel is different and set to default values within the dataset. The number of pulses
and the pulse duration can be modified using the Bank Note Validator Currency Manager
Software. A maximum of 16 channels can be used.
Connections:
Pin
Name
Type
Description
1
Vend 1
Output
Credit pulse stream output
2
Vend 2
Output
Not used
3
Vend 3
Output
Not used
4
Vend 4
Output
Not used
5
Inhibit
1
Input
Inhibit channel 1 by holding this pin HIGH, hold LOW to
enable
6
Inhibit
2
Input
Inhibit channel 2 by holding this pin HIGH, hold LOW to
enable
7
Inhibit
3
Input
Inhibit channel 3 by holding this pin HIGH, hold LOW to
enable
8
Inhibit
4
Input
Inhibit channel 4 by holding this pin HIGH, hold LOW to
enable
9
Busy
Output
Active LOW when the NV200 is transporting, reading or
stacking a note
10
Escrow
Input
Not Used
11
-
-
Do not connect
12
-
-
Do not connect
13
Factory Use Only
Do not connect
14
Factory Use Only
Do not connect
15
+Vin
Power
Nominal 12V DC supply
16
0V
Ground
0V supply
Table 11
- Pulse Mode Pin Description
Note: Channels higher than four cannot be individually inhibited, but will be globally inhibited
if inhibits 1 to 4 are held high.
NV200 Operations Manual 14