Copyright Innovative Technology Ltd 2008 GA620-1
VALIDATOR HEAD UNIT REMOVAL
To remove the head unit from the
validator, first unlock the ‘Cashbox
& Head Release Lock’ (if fitted). Lift
the silver ‘Head Release Latch’
located on the front of the
validator, slide the head unit
forward and lift up away from the
chassis.
To replace the head unit, align the
lugs on the chassis with the groove
on the underside of the head
assembly and slide the head
assembly backwards until it clicks
securely into place
Figure 9
– Validator head removal
8.3 APPENDIX C – ESCROW FUNCTION
The NV200 has a single note escrow facility (pin 10) used in Parallel, Pulse and Binary
modes. This allows the Validator to hold onto the note once accepted, and then only
stack the note in the cash box when the host machine confirms that the Vend operation
has been completed. If no confirmation of the Vend is received then the note will be
returned to the customer after 30 seconds, (see Figure 10 – Escrow Timing Diagram).
Figure 10
- Escrow Timing Diagram
If the host machine itself aborts the transaction by setting the corresponding inhibit
input high, the note is returned immediately.
NV200 Operations Manual 26
Head release latch
Do not wait more
than 30 seconds for
the 2
nd
vend
confirmation signal
Escrow
Vend Signal
30sec Max.
100ms
100ms
Escrow
Vend Signal
Inhibit
Inhibit rejection can be
at any time during the
30 second decision
period after completion
of the vend