INSTRUCTIONS
SETUP
1.
Place the air purifier so that it is in the upright, vertical position.
2.
Plug the machine into a standard 120 volt outlet.
Note: Each unit needs 3.6amps to operate.
3.
Power the unit on and adjust the speed by turning the variable speed control. The maximum
speed is 500 CFM.
4.
The air purifier can be operated in the vertical or horizontal position, depending on the exact
situation. At this point, adjust the machine to the optimal position.
5.
When the machine total working time add up to 2000 hours, the filter replacement
warning light on the control panel lights up to remind you to replace the
filter.
(To reset the machine, it had to push the UV-C light
Switch 3 times continuously in 3 seconds after Reset the filter service time )
6.
UV-C sterilization lamp fault detection function: when the UV-C sterilization lamp does not work, the
buzzer will keep ringing.
THE CONTROL PANEL
Variable Speed Control
Variable speed control is used to adjust the power of the machine.Turn the knob in a clockwise
direction, to increase the speed from minimum speed to maximum, the minimum speed setting is
located immediately close to OFF.
Auxiliary Outlet
If more air filtration is necessary for a space, you can "daisy chain" or link up to 3 air purifier to the
same outlet. There is a maximum amperage of 12 when the units are turned off, a maximum of 8
amps when the units are turned on. Other equipment can be plugged into the same outlet as the
air purifier as long as it doesn't go above the max amperage.
Overload protector
If the current through the socket exceeds 15 Amps, the current protector will protect the device. If
this happens, the current protector will cut off the power supply to the socket. The socket will not be
energized until reset is pressed.
Timer
Used to time the running time of the device. Start timing when the device is running, and pause
timing when the device is stopped.
Control function