NOTICE:
This Innovolt Device features internal protection for the Line-Neutral surge protection
component that will permanently disconnect the power to the load at the end of its useful life
indicating that the Innovolt Device needs to be replaced. This Innovolt Device also features
internal protection for the Line-Ground and Neutral-Ground surge protection components that
will disconnect these components at the end of their useful life but will maintain power to the
load without L-G and N-G protection.
This Innovolt Device complies with UL1449 3rd Edition, UL1363, UL497A, UL497B and UL1283
5th Edition.
LIMITED WARRANTY:
INNOVOLT warrants its products to be free from defects in materials and workmanship under
normal use and service for the lifetime of the product. This warranty is not transferable.
INNOVOLT’s obligation under this warranty is limited to repairing or replacing, at its sole option,
any such defective products. To obtain service under warranty you must obtain a Returned
Material Authorization (RMA) number from INNOVOLT or an INNOVOLT Service center with
transportation charges prepaid and must be accompanied by a brief description of the problem
and proof of date and place of purchase. This warranty applies only to original purchase.
INNOVOLT’s obligation under this warranty at all times will be limited to the purchase price paid
for the INNOVOLT product or the replacement cost of the INNOVOLT product at the company’s
discretion. Please refer to the detailed explanation of the limited warranty terms and conditions
at innovolt.com/support.
PARAMETER
TEL
DATA
Connector
RJ11
RJ45 (CAT5E)
Clamping Voltage
230 Vac - 250Vac
5 Vac - 15 Vac
Protected Lines
L1 - G / L2 - G
ALL
PARAMETER
PM15
PM20
Nominal Operating Voltage
120 Vac, 60 Hz
Over Voltage Limit
> 145 Vac
Under Voltage Limit
< 90 Vac
Maximum Continuous Current
15A
20A
Voltage Surge per UL 1449
3000 Joules
500 Vac L-N
800 Vac L-G
800 Vac N-G
Current Surge Limit
< 15A
< 20A
SPECIFICATIONS:
TEL / DATA:
ELECTRICAL:
INSTALLATION:
• Caution: the Innovolt Device is intended for indoor use in dry conditions.
• Plug the INPUT CORD into a 3-prong grounded outlet.
• Check to see that the GND LED is illuminated green. This confirms that the ground circuit is OK.
If the GND LED is glowing red, it indicates a faulty or nonexistent ground circuit. This must be
corrected prior to using the Innovolt Device as it is only intended for use in facilities that are wired
to the applicable Electric Code(s).
• The PWR/DATA LED will glow green to indicate that the Innovolt Device unit is operational and
ready for use.
• Plug the power cord from your electrical equipment into the Innovolt Device.
RJ11/RJ45 CONNECTION:
If you intend to use your Innovolt Device to protect RJ11/
RJ45 connected equipment, pass the RJ11/RJ45 line(s)
through the jacks on the Innovolt Device as illustrated.
Connect the RJ11/RJ45 line(s) from your wall outlet to the
INPUT jack on the Innovolt device. Connect the RJ11/
RJ45 line(s) from the equipment you intend to protect
into the OUTPUT jack on the Innovolt device.
INDICATIONS:
GND:
• GREEN LED ON: Ground connection at
outlet OK
• RED LED ON:Ground connection at outlet
faulty. Repair per applicable electric code.
Caution: risk of Electric Shock. Do not plug into another relocatable power tap. Do not install this device if there
is not at least 10 meters (30 feet) or more of wire between the electrical outlet and the electrical service panel.
PWR/DATA:
GREEN LED ON
• AC line voltage within normal limits
• Optical Data download possible
with Power Doctor optical reader
(sold separately)
OV / UV:
• RED LED ON: Voltage is outside of safe
limits and load is disconnected
• RED LED FLASHING: Event recovered
VOLTAGE SURGE:
• RED LED FLASHING: Voltage surge has
occurred
CURRENT SURGE:
• RED LED FLASHING: Current surge has
occurred