Version 1.0 09/08/2017
http://www.inorea.com
34
No.
Code
Parameter name
Setting range
Factory default Change
Reference page
86.
F4.00
V/F curve setting
0: linear V/F curve
1: multi-point V/F curve
2: square V/F curve
3:1.25th power V/F curve
4:1.75th power V/F curve
0
★
63
87.
F4.01
Torque boost
0.0%: automatic torque boost
0.1% to 30.0%
0.0%
☆
64
88.
F4.02
Torque boost cut-off
0.0% to 50.0% (relative to rated
frequency of motor)
20.0%
★
64
89.
F4.03
V/F frequency point 1
0.00Hz to F4.05
0.00Hz
★
64
90.
F4.04
V/F voltage point 1
0.0% to 100.0%
0.0%
★
64
91.
F4.05
V/F frequency point 2
F4.03 to F4.07
0.00Hz
★
64
92.
F4.06
V/F voltage point 2
0.0% to 100.0%
0.0%
★
65
93.
F4.07
V/F frequency point 3
F4.05 to b0.04 (rated motor
frequency)
0.00Hz
★
65
94.
F4.08
V/F voltage point 3
0.0% to 100.0%
0.0%
★
65
95.
F4.09
V/F slip compensation
limit
0.0 to 200.0%
0.0%
☆
65
5-1-7.F5 Group - Vector control group
No.
Code
Parameter name
Setting range
Factory default Change
Reference page
96.
F5.00
Speed loop proportional
gain 1
0 to 100
20
☆
65
97.
F5.01
Speed loop integral time 1
0.01 to 10.00s
0.50 s
☆
66
98.
F5.02
Switching low point
frequency
0.00Hz to F5.05
5.00Hz
☆
66
99.
F5.03
Speed loop proportional
gain 2
0 to 100
15
☆
66
100.
F5.04
Speed loop integral time 2
0.01 to 10.00s
1.00
☆
66
101.
F5.05
Switching high point
frequency
F5.02 to F0.08 (maximum
output frequency)
10.00Hz
☆
66
102.
F5.06
VC slip compensation
coefficient
50 to 200.0% (rated inverter
current)
100%
☆
66
103.
F5.07
Torque upper limit setting
0.0 to 200%
150%
☆
67
5-1-8.F6 Group - Keyboard and display
No.
Code
Parameters
Setting range
Factory default Change
Reference page
104.
F6.00
STOP/RST key stop
0: only active to panel control
3
☆
67