Code
Parameter name
Setting range
Factory default
Change
Multi-speed operation setting
5
PID control setting
6
Remote communications setting
7
Select the inverter frequency command input channels, there are eight kinds of given frequency channels:
0: Keyboard setting: to achieve by modifying function code F0.01 "keyboard set frequency" value.
1: Analog AI1 setting
2: Analog AI2 setting
3: Panel potentiometer setting
Refers to that the frequency is determined by the analog input terminals, VFR-013 inverter is equipped with standard two-
way analog input terminals (AI1, AI2), AI1/AI2 voltage and current optional (0V to 10V/0mA to 20mA), it can be switched
by the jumpers JP2 and JP3 on control panel. The corresponding relationship between AI1, AI2 input voltage value and the
target frequency can be set through F1 function code by user.
Panel potentiometer analog input voltage of 0V to 10V.
4: Analog AI1 + AI2 setting: refers to that the frequency is set by the analog input terminals.
Note: when the analog AI1/AI2 is selected as 0 to 20mA input, the voltage corresponding to 20mA is 10V
5: Multi-speed operation setting: when multi-speed operation setting mode is selected, the inverter will run at multi-speed
mode. Select current stage through setting multi-speed terminal combinations of F1 group; determine the running
frequency of current stage through parameters of E1 group.
6: PID control setting: when PID control setting mode is selected, the inverter will run at PID control mode. At this point,
you need to set E2 group "PID function group". The inverter's operation frequency is the frequency value after PID function
is applied. Where the meanings on PID given source, given quantity and feedback source, etc. Please refer to the
introduction of E2 group "PID function".
7: Remote communication setting: frequency command is set by the host computer through the communication. For
details, please refer to F9 group communication protocol.
F0.03
Keyboard and terminal
UP/DOWN setting
valid, and the inverter power failure with
data storage
0
0
☆
valid, and the inverter power failure
without data storage
1
UP/DOWN setting invalid
2
Valid when running, invalid when stop
3
Set the frequency through keyboard
▲
and
▼
keys and input terminals UP/DOWN (frequency setting
increment/frequency setting decrement) function, the setting can be combined with other frequency setting channels.
Notably tuning the output frequency is required after completion of the commissioning process in the control system
0: valid, and the inverter power failure with data storage You can set the frequency command that the set frequency value
is saved after the inverter with power failure. the set frequency will restored to the frequency at the last power-down
when the inverter power-down and power-up again.
1: valid, and the inverter power failure without data storage You can set the frequency command that the set frequency
value is not saved after the inverter with power failure.
2: UP/DOWN setting is invalid, keyboard
▲
and
▼
keys and input terminals UP/DOWN function is invalid.
3: Set keyboard
▲
and
▼
keys and terminal UP/DOWN function setting as valid when running, set keyboard
▲
and
▼
keys and input terminals UP/DOWN setting as not save when stop.
Note: after user restores the default value of function parameters of the inverter, the frequency value set by keyboard and
input terminals UP/DOWN function is the factory setting value.
F0.04
Command source channel
Keyboard command channel
0
0
★
Terminal command channel
1
Communication command channel
2
Select inverter control command channel. Inverter control command include: start, stop, forward, reverse, jog and fault
reset,etc.
0: keyboard command channel; RUN, STOP/RESET keys on keyboard is used to run commands
1: terminal command channel; multi-function input terminal forward, reverse, forward jog and reverse jog, etc is used to
run commands.
2: communication command channel; the host computer runs commands through the communication method.
F0.05
Acceleration time 1
0.1 to 3600.0s
Depends on models
☆
F0.06
Deceleration time 1
0.1 to 3600.0s
Depends on models
☆