2 Wiring
2
- 20 -
2.3.4 Analog Monitoring Signal Terminal Connector CN5
The following figure shows pin layout of the analog monitoring signal terminal connector CN5.
Figure 2-8 Analog monitoring signal terminal connector
1
3
2
4
No.
Definition
1
GND
2
AO1
3
GND
4
AO2
IS620P-S5R5
Corresponding interface circuit:
Analog output: -10 to +10 V
Maximum output current: 1 mA
2.4 Cables and Options
2.4.1 Cable Model
Table 2-5 Servo motor cables
Servo Motor
Model
Encoder Cable
Connector Kit
Optional Battery Kit for
Absolute Encoder Motor
L = 3.0 m
L = 5.0 m
L = 10.0 m
Standard Motor
ISMG1(G2)-
*******-U***
S6-
L-P01-3.0
S6-
L-P01-5.0
S6-
L-P01-10.0 S6-C5
CN1 connector
S6-C4 (battery, battery
box, size G, H)
S6-C9 (battery, battery
box, size I)
CN2 connector
20-29 military spec.
(elbow)
ISMG1(G2)-
*******-A3**
S6-
L-P21-3.0
S6-
L-P21-5.0
S6-
L-P21-10.0 S6-C6
CN5 connector
Note
The encoder cable package of the servo motor includes the CN1 connector.
S6-C6 is DB15 connector kit including CN5 connector, and is sued for fully closed-loop input.
If fully closed-loop is not required, only S6-C5 is necessary; if fully closed-loop is required, both
S6-C5 and S6-C6 need to be purchased.
Table 2-6 Communication cables
Model
Description
S6-L-T00-3.0
Servo drive to PC communication cable
S6-L-T01-1.0
Communication cable for multi-drive parallel connection
S6-L-T02-2.0
Servo drive to PLC communication cable
S6-L-T03-0.0
Plug for termination resistor for servo drive communication
Summary of Contents for IS650P Series
Page 1: ......
Page 101: ...100 Revision History Date Version Change Description March 2017 A00 First issue...