5 Troubleshooting
5
- 65 -
Function
Code
Parameter Name
Setting Range
Unit
Default
ET Pro CM
H00-30 Encoder selection (Hex)
Ox000: Common incremental encoder
(UVW-ABZ)
0x013: Inovance 20-bit serial encoder
1
0x013
Po
St
-
H00-31 PPR of encoder
0 to 1073741824
P/r
1048576 Po
St
-
H00-33 Electrical angle of signal Z 0.0 to 360
°
180
Po
St
-
H00-34 Electrical angle of phase U
rise edge
0.0 to 360
°
180
Po
St
-
Group H01: Servo Drive Parameters
Function Code
Parameter Name
Setting Range
Unit Default
ET
Pro
CM
H01-00
MCU firmware version
0 to 65535
-
-
-
Dp
-
H01-01
FPGA firmware version
0 to 65535
-
-
-
Dp
-
H01-02
Servo drive SN
0 to 65535
-
-
Po
St
-
Group H02: Basic Control Parameters
Function
Code
Parameter Name
Setting Range
Unit Default ET Pro CM
H02-00 Control mode selection
0: Speed mode
1: Position mode
2: Torque mode
3: Torque mode/Speed mode
4: Speed mode/Position mode
5: Torque mode/Position mode
6: Torque mode/Speed mode/Position
mode
-
1
Im
St
-
H02-01 Absolute system selection
0: Incremental position mode
1: Absolute position linear mode
2: Absolute position rotating mode
-
0
Po
St
ALL
H02-02 Rotating direction selection
0: CCW direction as forward direction
(phase A advancing phase B)
1: CW direction as forward direction
(phase A lagging phase B
-
0
Po
St
PST
H02-03 Output pulse phase
0: CCW direction as forward direction
(phase A advancing phase B)
1: CW direction as forward direction
(phase A lagging phase B)
-
0
Po
St
PST
H02-05 Stop mode at S-ON off
0: Coast to stop, keeping de-
energized state
1: Emergency stop, keeping de-
energized state
-
0
Im
St
PST
H02-06 Stop mode at NO.2 fault
0: Coast to stop, keeping de-
energized state
1: Emergency stop, keeping de-
energized state
-
0
Im
St
PST
Summary of Contents for IS650P Series
Page 1: ......
Page 101: ...100 Revision History Date Version Change Description March 2017 A00 First issue...
Page 102: ......