6 Parameter Table
6
- 70 -
Function
Code
Parameter Name
Setting Range
Unit Default ET Pro CM
H04-53 AO2 signal selection
00: Motor speed
(1 V/1000 RPM)
01: Speed reference
(1 V/1000 RPM)
02: Torque reference
(1 V/1 time of rated motor torque)
03: Position deviation
(0.05 V/1 reference unit)
04: Position deviation
(0.05 V/Enc)
05: Position reference speed
(1 V/1000 RPM)
06: Positioning completed (positioning
completed: 5 V, positioning not completed: 0 V)
07: Speed feedforward (1 V/1000 RPM)
08: AI1voltage
09: AI2 voltage
-
0
Im
Ru
-
H04-54 AO2 offset voltage
-10000 to 10000
mV
5000
Im
Ru
-
H04-55 AO2 multiplying factor -99.99 to 99.99
times 1.00
Im
Ru
-
Group H05: Position Control Parameters
Function
Code
Parameter Name
Setting Range
Unit
Default ET Pro CM
H05-00 Position reference
source
0: Pulse input
1: Step setting
2: Multi-position reference
-
0
Im
St
P
H05-01 Pulse input terminal
selection
0: Low-speed terminals
1: High-speed terminals
-
0
Im
St
P
H05-02 Pulses per one motor
revolution
0 to 1048576
P/r
0
Po
St
P
H05-04
Time constant of first-
order low-pass filter
0 to 6553.5
ms
0.0
Im
St
P
H05-05 Step amount
-9999 to 9999
Ref
50
Im
St
P
H05-06 Time constant of moving
average filter
0.0 to 128.0
ms
0.0
Im
St
P
H05-07 Electronic gear ratio 1
(numerator)
1 to 1073741824
-
1048576 Im Ru
P
H05-09 Electronic gear ratio 1
(denominator)
1 to 1073741824
-
10000
Im Ru
P
H05-11 Electronic gear ratio 2
(numerator)
1 to 1073741824
-
1048576 Im Ru
P
H05-13 Electronic gear ratio 2
(denominator)
1 to 1073741824
-
10000
Im Ru
P