6 Parameter Table
6
- 83 -
Function
Code
Parameter Name
Setting Range
Unit
Default ET Pro CM
H0F-13 Filter time constant of hybrid
vibration suppression
0 to 6553.5
ms
0
Im Ru
P
H0F-16 Full closed-loop position
deviation counter
-1073741824 to 1073741824
Ext enc
0
-
D
P
H0F-18 Feedback pulse counter of
internal encoder
-1073741824 to 1073741824
Int enc
0
-
D
P
H0F-20 Feedback pulse counter of
external encoder
-1073741824 to 1073741824
Ext enc
0
-
D
P
Group H11: Multi-Position Function Parameters
Function
Code
Parameter Name
Setting Range
Unit
Default ET Pro
CM
H11-00 Multi-position running mode
0: Stop after running single
cycle
1: Cyclic running
2: DI switchover
3: Sequential running
-
1
Im
St
P
H11-01
Number of position reference profile
1 to 16
-
1
Im
St
P
H11-02 Margin processing method
0: Complete the remaining
distance
1: Start running again from
1st position
-
0
Im
St
P
H11-03 Time unit
0: ms; 1: s
-
0
Im
St
P
H11-04 Displacement reference type
0: Relative displacement
reference
1: Absolute displacement
reference
-
0
Im
St
P
H11-05 Start position of sequential running 0 to 16
-
0
Im
St
P
H11-12 1st displacement
-1073741824 to
1073741824
Ref
10000
Im
Ru
P
H11-14 Maximum running speed of 1st
displacement
1 to 6000
RPM
200
Im
Ru
P
H11-15 Acceleration/Deceleration time of
1st displacement
0 to 65535
ms (s)
10
Im
Ru
P
H11-16 Waiting time after 1st displacement 0 to 10000
ms (s)
10
Im
Ru
P
H11-17 2nd displacement
-1073741824 to
1073741824
Ref
10000
Im
Ru
P
H11-19 Maximum running speed of 2nd
displacement
1 to 6000
RPM
200
Im
Ru
P
H11-20 Acceleration/Deceleration time of
2nd displacement
0 to 65535
ms (s)
10
Im
Ru
P
H11-21 Waiting time after 2nd displacement 0 to 10000
ms (s)
10
Im
Ru
P
H11-22 3rd displacement
-1073741824 to
1073741824
Ref
10000
Im
Ru
P
H11-24 Maximum running speed of 3rd
displacement
1 to 6000
RPM
200
Im
Ru
P