2 Wiring
2
- 8 -
Drive Model
Regenerative Resistor Specifications
Resistance (Ω)
Power (kW)
IS650PT060IUX
16
2
IS650PT075IUX
8
5.5
IS650PT091IUX
IS650PT112IUX
More descriptions of the table are as follows:
●
The preceding table lists the typical reference data. Selection of the regenerative resistor is related the
actual motor power, and also the system inertia, deceleration time, and energy of the potential energy
load.
The larger the system inertia, the shorter the deceleration time, and the more frequent the braking is. In
this case, you need to select a regenerative resistor of larger power and smaller resistance. Select the
appropriate resistance and power based on actual conditions; for details on how to make calculation,
contact Inovance.
●
The resistance and power must not be lower than the recommended value.
●
Set the parameters of the regenerative resistor in H02-25, H02-26, H02-27 based on actual conditions.
Otherwise, a fault will be tripped.
1.5 Motor Dimensions
1. Solid shaft, forced ventilation motor (ISMG2)
Standard accessory: type-A round-
head common plain key 14x9x90
GB / T 1096
The mounting baseplate is
optional, and is used only
when required.
Connector
Encoder Side
Military spec.
MIL-DTL-5015 series 3102E20-29P
Motor Model
L (mm)
K (mm)
Weight (kg)
ISMG2-42D20CD-U***FA
ISMG2-42D20CD-A3**FA
575
360
127
ISMG2-57D20CD-U***FA
ISMG2-57D20CD-A3**FA
625
370
158.4