6 Parameter Table
6
- 90 -
Function
Code
Parameter Name
Setting Range
Unit
Default ET Pro CM
H17-23 VDI12 logic selection
0: Valid when logic is 1
1: Valid when logic changes from 0 to 1
-
0
St
Ru
-
H17-24 VDI13 function selection
0 to 37
-
0
St
Ru
-
H17-25 VDI13 logic selection
0: Valid when logic is 1
1: Valid when logic changes from 0 to 1
-
0
St
Ru
-
H17-26 VDI14 function selection
0 to 37
-
0
St
Ru
-
H17-27 VDI14 logic selection
0: Valid when logic is 1
1: Valid when logic changes from 0 to 1
-
0
St
Ru
-
H17-28 VDI15 function selection
0 to 37
-
0
St
Ru
-
H17-29 VDI15 logic selection
0: Valid when logic is 1
1: Valid when logic changes from 0 to 1
-
0
St
Ru
-
H17-30 VDI16 function selection
0 to 37
-
0
St
Ru
-
H17-31 VDI16 logic selection
0: Valid when logic is 1
1: Valid when logic changes from 0 to 1
-
0
St
Ru
-
H17-32 VDO virtual level
-
-
-
-
D
-
H17-33 VDO1 function selection
0 to 22
-
0
St
Ru
-
H17-34 VDO1 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-35 VDO2 function selection
0 to 22
-
0
St
Ru
-
H17-36 VDO2 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-37 VDO3 function selection
0 to 22
-
0
St
Ru
-
H17-38 VDO3 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-39 VDO4 function selection
0 to 22
-
0
St
Ru
-
H17-40 VDO4 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-41 VDO5 function selection
0 to 22
-
0
St
Ru
-
H17-42 VDO5 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-43 VDO6 function selection
0 to 22
-
0
St
Ru
-
H17-44 VDO6 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-45 VDO7 function selection
0 to 22
-
0
St
Ru
-
H17-46 VDO7 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-47 VDO8 function selection
0 to 22
-
0
St
Ru
-
H17-48 VDO8 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-49 VDO9 function selection
0 to 22
-
0
St
Ru
-
H17-50 VDO9 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
H17-51 VDO10 function selection
0 to 22
-
0
St
Ru
-
H17-52 VDO10 logic selection
0: Output 1 when function valid
1: Output 0 when function valid
-
0
St
Ru
-
Summary of Contents for IS650P Series