6 Parameter Table
6
- 97 -
No.
Function
Symbol
Function Name
Description
Remarks
FunIN.37
PulseInhibit
Pulse input
inhibited
When the position reference
source is pulse input (H05-
00 = 0) in the position control
mode:
Invalid: Respond to pulse input
Valid: Not respond to pulse
input
It is recommended that the
logic of the corresponding
terminal be set to level valid.
Output Function Description
FunOUT.1
S-RDY
Servo ready
The servo drive is in ready
state and can receive the
S-ON signal.
Valid: Servo drive ready
Invalid: Servo drive not ready
Servo not ready: A No. 1 or 2
fault occurs in the servo drive,
or the DI emergency stop
signal is active.
FunOUT.2
TGON
Motor rotation
output
Valid: Motor speed absolute
value after filter smaller than
H06-16
Invalid: Motor speed absolute
value after filter equal to or
larger than H06-16
-
FunOUT.3
ZERO
Zero speed
signal
Invalid: The absolute deviation
between the motor speed
feedback and the speed
reference is larger than the
setting of H06-19.
Valid: The absolute deviation
between the motor speed
feedback and the speed
reference is smaller than or
equal to the setting of H06-19.
-
FunOUT.4
V-CMP
Speed
consistent
In the speed control mode,
when the absolute value of the
deviation between the motor
speed and the speed reference
is smaller than the value of
H06-17, this signal is active.
-
FunOUT.5
COIN
Positioning
completed
In the position control mode,
when the position deviation
pulses reach the value of H05-
21, this signal is active.
-
FunOUT.6
NEAR
Positioning
near
In the position control mode,
when the position deviation
pulses reach the value of H05-
22, this signal is active.
-
FunOUT.7
C-LT
Torque limit
Confirming torque limit:
Valid: Motor torque limited
Invalid: Motor torque not
limited
-