6 Parameter Table
6
- 78 -
Function
Code
Parameter Name
Setting Range
Unit Default ET Pro CM
H09-12 1st notch frequency
50 to 4000
Hz
4000
Im Ru PS
H09-13 1st notch width level
0 to 20
-
2
Im Ru PS
H09-14 1st notch depth level
0 to 99
-
0
Im Ru PS
H09-15 2nd notch frequency
50 to 4000
Hz
4000
Im Ru PS
H09-16 2nd notch width level
0 to 20
-
2
Im Ru PS
H09-17 2nd notch depth level
0 to 99
-
0
Im Ru PS
H09-18 3rd notch frequency
50 to 4000
Hz
4000
Im Ru PS
H09-19 3rd notch width level
0 to 20
-
2
Im Ru PS
H09-20 3rd notch depth level
0 to 99
-
0
Im Ru PS
H09-21 4th notch frequency
50 to 4000
Hz
4000
Im Ru PS
H09-22 4th notch width level
0 to 20
-
2
Im Ru PS
H09-23 4th notch depth level
0 to 99
-
0
Im Ru PS
H09-24 Obtained resonance
frequency
0 to 2
Hz
0
-
D
PS
H09-30 Torque disturbance
compensation gain
0.0 to 100.0
%
0.0
Im Ru PS
H09-31 Time constant of torque
disturbance observer filter
0.00 to 25.00
ms
0.50
Im Ru PS
H09-38 Frequency of low-
frequency resonance
1.0 to 100.0
Hz
100.0
Im Ru
P
H09-39 Filter setting of low-
frequency resonance
0 to 10
-
2
Im Ru
P
Group H0A: Fault and Protection Parameters
Function
Code
Parameter Name
Setting Range
Unit
Default
ET Pro CM
H0A-00 Power input phase loss
protection
0: Enable faults and inhibit
warnings
1: Enable faults and warnings
2: Inhibit faults and warnings
-
0
Im
Ru
-
H0A-03 Retentive at power failure
0: Disabled
1: Enabled
-
0
Im
Ru
-
H0A-04 Motor overload protection gain 50 to 300
%
100
Im
St
-
H0A-08 Overspeed threshold
0 to 10000
RPM
0
Im
Ru PST
H0A-09 Maximum position pulse
frequency
100 to 4000
kHz
4000
Im
St
P
H0A-10 Threshold of position deviation
excess
1 to 1073741824
Enc/
Ref
3145728
Im
Ru
P
H0A-12 Runaway protection function
0: Disabled
1: Enabled
-
1
Im
Ru PST
H0A-16
Position deviation threshold
for low-frequency resonance
suppression
1 to 1000
Enc
5
Im
Ru
P