6. Description of Parameters
- 118 -
6
Ƶ
Pulse Reference (DI5)
Frequency reference is input by means of DI5 (high-speed pulse). Signal specification
of pulse reference is 9 to 30 V (voltage range) and 0 to 100 kHz (frequency range). The
corresponding value 100% of pulse reference corresponds to the value of F0-10 (max.
frequency).
Note
Main frequency reference set via pulse reference and pulse output of the FM
terminal (F5-00 = 1) cannot be used simultaneously.
F4-28 to F4-32 set relationship between pulse input (from DI5 only) and corresponding
percentage. It has the same function and usage as AI curve 1 does. Refer to
Step 1: Set
AI curve.
Function Code
Parameter Name
Setting Range
Default
F4-28
Pulse min. input
0.00 kHz to F4-30
0.00 kHz
F4-29
Corresponding percentage
of pulse min. input
-100.00% to 100.0%
0.0%
F4-30
Pulse max. input
F4-28 to 50.00 kHz
50.00 kHz
F4-31
Corresponding percentage
of pulse max. input
-100.00% to 100.0%
100.0%
F4-32
3XOVH¿OWHUWLPH
0.00s to 10.00s
0.10s
Figure 6-19 Pulse input at DI5 to control frequency reference
Note:
100.0% corresponds to
max. frequency (F0-10).
DI5
Use pulse signals to control
frequency reference
(valid for DI5 only)
COM
Final
frequency
reference
Select main frequency
reference as final
frequency reference.
Set the relationship between
the pulse input (from DI5 only)
and the corresponding
percentage via F4-28 to F4-32.
Select pulse as main
frequency reference
setting channel.
F0-07 (units
position) = 0
F4-33 (hundreds
position) = 2
F0-03 = 5
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......
Page 350: ......