Appendix
- 321 -
12
Para. No.
Para. Name
Setting Range
Default
Property
Page
Group F9: Fault and Protection
F9-00
Motor overload protection
0: Disabled
1: Enabled
1
ƿ
153
F9-01
Motor overload protection gain
0.20 to 10.00
1.00
ƿ
153
F9-02
Motor overload pre-warning
FRHI¿FLHQW
50% to 100%
80%
ƿ
154
F9-07
Detection of short-circuit to
ground upon power-on
Short-circuit to ground
protection before running
0: Disabled
1: Enabled
Short-circuit to ground
protection at power-on
0: Disabled
1: Enabled
01
ƿ
-
F9-08
Braking unit applied voltage
650 to 800 V
760 V
ƾ
151
F9-09
Auto reset times
0 to 20
0
ƿ
155
F9-10
Selection of DO action during
auto reset
0: Not act
1: Act
0
ƿ
155
F9-11
Delay of auto reset
0.1s to 100.0s
1.0s
ƿ
155
F9-12
Input phase loss/pre-charge relay
protection
0: Disabled
1: Enabled
Input phase loss
0: Disabled
1: Enabled
Pre-charge relay protection
11
ƿ
154
F9-13
Output phase loss protection
During running
0: Disabled
1: Enabled
Before running
0: Disabled
1: Enabled
01
ƿ
155
F9-14
1st fault type
0: No fault
1: Reserved
2: Overcurrent during
acceleration
3: Overcurrent during
deceleration
4: Overcurrent at constant
speed
-
Ɣ
-
Summary of Contents for MD290 Series
Page 1: ......
Page 79: ...3 Electrical Installation 78 3 ...
Page 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Page 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Page 227: ...7 Interfaces and Communication 226 7 ...
Page 285: ...10 Troubleshooting 284 11 ...
Page 349: ......