Appendix A Parameter Table
- 100 -
Para.
No.
Para. Name
Setting Range
Default
Property
F2-22
Output voltage filter
time
0.000 to 0.010s
0.000s
☆
F2-23
Zero speed lock
0: Disabled
1: Enabled
0
★
F2-24
SVC/FVC overvoltage
suppression coefficient
KP
0 to 1000
40
☆
F2-25 Acceleration rate
compensation gain
0 to 200
0
☆
F2-26 Acceleration rate
compensation filter
0 to 500
10
☆
F2-27
SVC/FVC overvoltage
suppression function
0: Disabled
1: Enabled
1
☆
F2-28
Cut-off frequency of
torque filter
50 to 1000 Hz
500 Hz
☆
F2-29
Synchronous motor
initial angle detection
current
50% to 180%
80%
☆
F2-30
Speed loop parameter
auto-calculation
0: Disabled
1: Enabled
0
★
F2-31
Expected speed loop
bandwidth at high
speed
1.0 to 200.0 Hz
10.0 Hz
☆
F2-32
Expected speed loop
bandwidth at low
speed
1.0 to 200.0 Hz
10.0 Hz
☆
F2-33
Expected speed loop
bandwidth at zero
speed
1.0 to 200.0 Hz
10.0 Hz
☆
F2-34 Expected speed loop
damping ratio
0.100 to 65.000
1.000
☆
F2-35
System inertia
(equivalent to startup
time)
0.001s to 50.000s
Model
dependent
★
F2-36
Single motor inertia (
kg*m
2
)
0.001 to 50.000
Model
dependent
★
F2-43
Inertia auto-tuning
and dynamic speed
reference (unit: 30%;
base value: rated motor
frequency)
0% to 100%
30%
★
F2-47
Inertia auto-tuning
0: Disabled
1: Enabled
0
★