Appendix A Parameter Table
- 133 -
Para.
No.
Para. Name
Setting Range
Default
Property
A1-08 Function selection for
AI2 used as DI
Refer to F4-00
0
★
A1-10 Active mode selection
for AI used as DI
Ones: AI1
0: High level active
1: Low level active
Tens: AI2
0: High level active
1: Low level active
00
★
Group A5: Control Optimization Parameters
A5-00 DPWM switchover
frequency upper limit
0.00 Hz to maximum frequency (F0-
10)
12.00Hz
☆
A5-01 PWM modulation mode 0: Asynchronous modulation
1: Synchronous modulation
0
☆
A5-02 Dead zone
compensation
0: Disabled
1: Enabled
1
★
A5-03
Random PWM depth
0: Random PWM invalid
1 to 10
0
☆
A5-04 Fast current limit
0: Disabled
1: Enabled
1
0
(asynchronous
motor in SVC)
☆
A5-05 Sampling delay
1 to 13
5
☆
A5-06
Undervoltage
threshold
60% to 140%
100.0%
☆
Group A6: AI Curve Setting
A6-00 AI curve 4 minimum
input
-10.00 V to A6-02 (AI curve 4 inflection
1 input)
0.00 V
☆
A6-01
Corresponding
percentage of AI curve
4 minimum input
-100.0% to +100.0%
0.0%
☆
A6-02
AI curve 4 inflection 1
input
A6-00 (AI curve 4 minimum input) to
A6-04 (AI curve 4 inflection 2 input)
3.00 V
☆
A6-03
Corresponding
percentage of AI curve
4 inflection 1 input
-100.0% to +100.0%
30.0%
☆
A6-04
AI curve 4 inflection 2
input
A6-02 (AI curve 4 inflection 1 input)
to A6-06 (AI curve 4 maximum input)
6.00 V
☆
A6-05
Corresponding
percentage of AI curve
4 inflection 2 input
-100.0% to +100.0%
60.0%
☆