3 Wiring
- 52 -
Type
Terminal
Symbol
Terminal Function
Performance
RJ45B
communication
interface
CAN1H
CAN_H of communication
signal
CANopen/CANlink supported
CAN1L
CAN_L of communication
signal
CGND
Ground of communication
signals
RS485+
RS485 communication
signal positive
RS485 internal bus, used for the
external LCD operating panel and
PC commissioning
RS485-
RS485 communication
signal negative
C7V
Power supply to the
external LCD operating
panel
Power supply to the external LCD
operating panel
C7V
Power supply to the
external LCD operating
panel
CGND
Ground of communication
signals
Ground of communication signals
CAN
communication
for
synchronization
control
CAN2H
CAN_H of CAN
communication signal
CAN2L
CAN_L of CAN
communication signal
CGND
Ground of CAN
communication signal
Relay terminal
TA/TB/TC
TA-TB: NC
TA-TC: NO
Axis 1 and axis 2 are shared.
Contact capacity: 250 VAC/3 A
(COSφ = 0.4)
DP
communication
interface (CN6)
Unconnected
/
1
2
3
4
5
6
7
8
9
C5V
NC
TR+
TR-
NC
CGND2
NC
NC
NC
Unconnected
/
TR+
DP bus positive
Unconnected
/
CGND2
Ground of DP bus power
supply
C5V
DP bus power supply
Unconnected
/
TR-
DP bus negative