background image

 

www.insigniarange.com

 

Last Modified: 13/02/2017

 

   

INSTALLATION MANUAL

 

           ES004

 

ATTENTION INSTALLERS:

 

These instructions must be 

 

left with the customer

 

30 Day Technical Support: 

01908 226545

 

(NOTE: This service is only available to customers from the day of delivery, 

please have your supplier

s details and your postcode to hand before calling)

 
 

Replacements Parts:

 inside of your warranty contact: 

www.insigniarange.co.uk/customerService.aspx

 

 

Spares/Replacements Parts:

 outside of your warranty 

 

contact 

0844 800 3069

 
 

www.insigniarange.co.uk

 

WARRANTY REG NO: __________________________

 

To claim your full 5 year warranty, register your shower within  90 days of delivery at:  www.insigniarange.co.uk/
warrantyreg.aspx. Standard 12 month warranty applies if outside this time period.

 

CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE 
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!

 

 

Summary of Contents for ES004

Page 1: ...ts Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __________________________ To claim your full 5 year warranty register your shower within 90 days of delivery at www insigniarange co uk warrantyreg aspx Standard 12 month warranty applies if outside t...

Page 2: ...tion Electrical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Sealing and Water Testing Control Panel Instructions Help Book Information Parts List 3 5 7 8 9 10 11 18 19 20 21 22 ...

Page 3: ...any years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Very easy 2 Badges Easy 3 Badges Moderate 4 Badges Harder than average 5 Badges Professional skills requi...

Page 4: ...ED ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN YOURS AND OTHERS SAFETY IS PARAMOUNT NEVER ATTEMPT THIS YOURSELF REMEMBER These showers are designed to be free standing and movable from their location should you have the need to replace anyth...

Page 5: ...te for electrician This product comes with 3 amp plug We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current laws and IP directives 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Always use protection against electrical surge Your shower should be treated the same as a hom...

Page 6: ...one Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Not Supplied Not Supplied Hardware Requirements A Steam Shower requires 2 x 1 Metre Braided Hose Not Supplied ...

Page 7: ... assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final fix What s In The Boxes Tray Box 1x Tray 1x Roof 2x Curved Rails 1 x AC DC 12V Adapter Glass Room 2x Door seals 2x Glass doors 2x fixed glass Column 1x Complete Column...

Page 8: ...eplacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Description Quantity SP097 Door Handles 2 SP043 Chrome Door Wheels 8 ST20 20mm Screws 20 ST35 35mm Screws 10 ST14 14mm Screws 6 ST25 25mm Screws 10 SW9 Small Washers 20 DB9 Drill Piece 1 Note In some cas...

Page 9: ...er plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is free standing and is designed to be pulled away from the wall Th...

Page 10: ...tem is for the steam generator drainage and will be con nected in the instructions later Now please level the tray by firstly placing the tray in its final location and then using a spirit level adjust the tray feet accordingly Once you are happy with the levelling of the tray you can pull it out to begin the main construction Step 1 Attach the uprights to the bottom curved rail using the ST35 scr...

Page 11: ...by the arrows Step 3 The next step is to attach both front uprights and the top rail In order to do this insert the front uprights over the glass seal as push on tightly as directed by the arrows in the image Now attach the top rail wide rail with logo and then screw into place using the ST35 screws Now place your completed front frame on the front of the shower tray as per the image on the right ...

Page 12: ...ound to the position shown in the image marked 2 Now repeat for the other side 1 2 1 Step 5 Now you have locked the two back panels in position Rubbergum the bottom of the column and align the back panels to the central column Once you are happy with the alignment run a bead of silicone up the edge of the column and fix together using the ST20 screws and SW9 Washers as per the image please note if...

Page 13: ...djustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a tight fit Now grease the...

Page 14: ...n the below image Next slide the shelf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recommend using a screwdriver ...

Page 15: ...roughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the image Now from the inside of the shower re attach the chrome pepper pot end and tighten Monsoon Head Attach the grey hose from your valve to the inner black tube using PTFE tape please note this only nee...

Page 16: ...Insignia shower as a reference point IF YOUR DIAL DOES NOT CORROSPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the wa ter and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew fully as this will drop within the chrome k...

Page 17: ...www insigniarange com Last Modified 13 02 2017 17 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna Speaker ...

Page 18: ...ry difficult Now on the OUTSIDE of the shower inspect each joint factory seal hose clip and jet by walking from one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal Please remember the location of the water may not be exactly where the...

Page 19: ...Instructions Button 1 VOL Volume Up Button 2 Down Arrow Radio Search Down Button 3 Up Arrow Radio Search Up Button 4 VOL Volume Down Button 5 Power On Off Button 6 Telephone Answer telephone Button 7 FM Radio On Off Button 8 LIGHT On Off Button 9 FAN On Off 1 2 3 4 5 6 7 8 9 ...

Page 20: ...www insigniarange com Last Modified 13 02 2017 20 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx ...

Page 21: ...lister pack SP152 Standard shower head SP166 Approximately 4 meters of U Style seals SP039 Fan model dependent SP274 Multi Coloured Ring Light Part Code Part Description SP300 Waste hose SP251 Transformer SP308 Magnetic door seals SP310 Rear door seals SP089 SP095 SP044 SP182 SP043 3 port 2 feed thermo static valve 3 Port Selector Cartridge On Off Water Mixer Valve Vernet Screw Fit Ther mostatic C...

Page 22: ...e used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered with ImageTraker Insignia is a registered trademark of Maclean International Ltd ...