Silicone Seal (vertical joints)

 

-

 

RubberGum (horizontal joints)

 

 

TESTING FOR WATER LEAKS

 

LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALENT TO CURE AND ENSURE 

THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING

 

Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model 

dependent) on your shower. 

We also advise to run a thin bead of silicone around the control panel.

 

Switch on the overhead shower NOT the massage jets, remember these will fire water out at you 

and are not suitable for checking leaks as they would normally only operate when a person is in 

front of them. DO NOT AIM THE HAND SHOWER AT THE JOINTS OF YOUR SHOWER AS THIS 

DOES NOT FALL UNDER 

NORMAL EVERYDAY USE

”. 

Adjust the feet to ensure the  direction of 

the water flows towards to the waste to prevent puddling.

 

Just use COLD water setting as hot will make cabin misty and condensate thus the inspection 

becomes very difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal, hose, 

clip and jet by walking from one side and going around to the back and then to the other side 

finishing at the front. If you have a small leak (normally caused through insufficient sealer or air 

bubble on assembly, dry the area thoroughly and reseal.

 

Please remember the location of the water may not be exactly where the leak is as it could have run 

around to a low point. Never seal your inner fittings unless necessary, remember you will see this 

for the life of the shower! Again leave to cure and check. Once you are happy check the shower 

functions i.e. jets for back massage, foot massage and finally hand shower (model dependent) 

check your joints to these functions at the rear again. Never use the shower until 

all

 checks have 

been made and the installer is 100% happy in the knowledge no leaks are present. 

 

Important Note:

 

 

 

It is not uncommon due to temperature changes, 

 

glass seals fitted into the frame 

lower horizontal and sides can and do shrink leaving a small gap. This is normal to prevent rubbers 
perishing or opening later in your showers life. Check yours now, any slight gaps simply seal neatly 

with a thin bead of silicone. This will prevent chances of leakage both now or later in life. 

 

All good?

 

Now push your shower FROM THE BASE and NEVER THE GLASS OR FRAME into its final resting 

position.

 

Happy Showering! 

Summary of Contents for ES007

Page 1: ...calling Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk...

Page 2: ...n Electrical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Control Panel Connections Sealing and Water Testing SUN Control Panel Instr...

Page 3: ...ny years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your f...

Page 4: ...D ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERT...

Page 5: ...cian This product comes with 13 amp plug s fitted with an RCD unit We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current...

Page 6: ...un Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Hardware Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste j...

Page 7: ...s assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the u...

Page 8: ...replacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code De...

Page 9: ...r plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a comb...

Page 10: ...www insigniarange com Last Modified 18 12 2017 10...

Page 11: ...ou have the need to replace anything Take the shower tub and remove all the protective wrapping and fit the waste In the side of the waste supplied in the optional fitting kit you will notice a spigot...

Page 12: ...ghts maybe pre fitted to the front fixed glass see above to the curved rails using the ST57 screws The end with the groove is designed to sit on the tray with the flat end connecting to the roof Pleas...

Page 13: ...017 13 Step 4 Now attach your inner uprights to your front fixed glass panels by inserting these over the thin rubber seals as shown by the arrows in the image please note that the front uprights will...

Page 14: ...Next screw the inner uprights to your curved rails using the ST25 screws for the top and for the bottom Step 6 Now meet the front of the shower with the back panels and screw together using the ST12 a...

Page 15: ...s Step 8 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of...

Page 16: ...Note Ensure all backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recomm...

Page 17: ...ve one for each end of the hose Attach the grey hose from your valve to the inner black tube using PTFE tape please note this only needs to be hand tight Over tightening will snap damage the inner bla...

Page 18: ...Insignia shower as a reference point IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the water and...

Page 19: ...www insigniarange com Last Modified 18 12 2017 19 Electric Box Connections Connect the cables below to the corresponding devices on the shower...

Page 20: ...shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this open...

Page 21: ...om one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area t...

Page 22: ...es Button 4 Press to set the desired time for the steam session Maximum time is 60 minutes Button 5 Press to activate the multi coloured lights Press again to turn them off Button 6 Press once to acti...

Page 23: ...ww insigniarange com Last Modified 18 12 2017 23 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Page 24: ...rnal Items SP273 Speaker SP228 Speaker cover SP280 Essential Control Panel SP152 Standard shower head Part Code Part Description SP300 Waste hose SP308 Magnetic door seals SP310 Rear door seals SP281...

Page 25: ...used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All...

Reviews: