Step 10

 

 

Insert remaining upright to the left of the curved glass panel. Drill and screw this 

into position using the 

ST20 

screws

 

and once fixed slide the flat rubber glass seal into 

this newly fitted upright on the inside (as of the green line in the image)

 

Please Note

: ensure you drill no deeper than 5mm.

 

Step 11

 

 

Pierce through the holes using a screwdriver to show pre

-

cut holes in the glass as 

indicated in the image. Now using the chrome 

L

” 

brackets, fix these to the outside of the 

glass panels using the provided nuts and bolts (

B22

) please ensure the bolt goes 

through the plastic cover holder (

PCH13)

 first

 

Align the shower panels until you are happy with the sitting of these and now using the 

ST25 

screws, screw the brackets to the tub

 

Now place the Chrome cover caps (

CPC16

) onto the cover holders (

PCH13

)

 

Step 10

 

Step 11

 

Back

 

Inside

 

Summary of Contents for INS8059R

Page 1: ...Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO ___...

Page 2: ...at care to ensure you get the best out of your build and have a shower that will last for many years to come OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Ver...

Page 3: ...rements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing SUN Control Pa...

Page 4: ...ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERTAK...

Page 5: ...wo methods 1 Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting direc...

Page 6: ...ade Silicone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Hardware Requirements Bacteria Resistant Sanitary Silicone for vertical joints Plumbers Mait for was...

Page 7: ...e use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carr...

Page 8: ...d Insignia Screw Pack VERY IMPORTANT Have you got everything If not please contact the Insignia Support Line on 01908 226545 Remember NEVER book your tradesman until everything has arrived been checke...

Page 9: ...plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a combi...

Page 10: ...insigniarange com Last Modified 27 01 2017 10...

Page 11: ...a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connected in the instructions later Now please level the tray by firstly placing the tra...

Page 12: ...e ST20 screws Step 2 please note if your column has a rubber seal at the bottom take the rubber off and apply silicone inside the rubber and replace Again Once you have completed a dry run and are hap...

Page 13: ...Once you are happy with the alignment then continue to screw the upright into place at the top and bottom using ST14 s Please note These are not pilot holed and you will need to use the DB6 1 2 1 2 1...

Page 14: ...ST35 screws Fix the front of the top curved rail onto the upright of the front fixed angled glass Please note in order to do this you will need to slide up the front fixed panel roughly 3 inches to e...

Page 15: ...holes to take the screws this is at a depth no deeper than 5mm Step 9 Apply silicone to specified area as shown on the diagram then take the front curved glass panel and insert into the upright Then u...

Page 16: ...r than 5mm Step 11 Pierce through the holes using a screwdriver to show pre cut holes in the glass as indicated in the image Now using the chrome L brackets fix these to the outside of the glass panel...

Page 17: ...o show pre cut holes in the glass as indicated in the image Now repeat the process from step 11 to secure the roof to the glass panels Step 13 Align the shower roof to your side panels and when you ar...

Page 18: ...uated on the bottom of the bracket Accessory Installation Tri Jet Steam System Locate the three holes in the glass panel Put the Tri Jet manifold as shown through and screw the three small outlets to...

Page 19: ...ding up and down Thermostatic Probe Insert the probe into the hole situated below the control panel roughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscrew...

Page 20: ...ad Door Wheels Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are facing towards the rail then hang the top wheels on to the top inner curved rail Now on the...

Page 21: ...exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew full...

Page 22: ...niarange com Last Modified 27 01 2017 22 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna Thermostatic probe 12V power Supply Spe...

Page 23: ...eam pod within your shower Make sure these are fitted in the correct positio n as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s cent...

Page 24: ...s shown below Follow the lights around in the order shown as this allows a consistent path around the entire roof and will leave you placing the last light next to the first light This is important as...

Page 25: ...insigniarange com Last Modified 27 01 2017 25 Roof cover After installing the LED light fixtures place the roof cover over the led cables as shown in the diagram...

Page 26: ...llow children to use the steam function This function is for ADULTS ONLY Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if y...

Page 27: ...misty and condensate thus the inspection becomes very difficult Now on the OUTSIDE of the shower inspect each joint factory seal hose clip and jet by walking from one side and going around to the bac...

Page 28: ...timer Button 3 Up Arrow Radio search higher frequency music track next song volume increase Button 4 Audio select To tune your radio channels firstly press the Audio Select button which looks like a m...

Page 29: ...dio channels firstly press the Audio Select button which looks like a musi cal note and a Bluetooth symbol Tuning your radio channels Step1 To connect a device via Bluetooth press the music function b...

Page 30: ...ock the panel Please Note When the control panel is locked none of the buttons will work except the unlock key Button 7 Down Arrow Radio search lower frequency music track previous song volume decreas...

Page 31: ...insigniarange com Last Modified 27 01 2017 31 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx...

Page 32: ...aste SP097 Chrome rectangular door handles SP240 Glass Shelf SP080 Head rest SP050 Seat rest SP196 Thermo sensor holder SP072 Door stoppers SP023 SP011 SP012 8 Pack Door Wheels Twin Door Wheels Single...

Page 33: ...onal Ltd All images are subject to copyright Images may not be used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or...

Reviews: