background image

 

www.insigniarange.com

 

Last Modified 08/02/2018

 

 27 

Silicone Seal (vertical joints)

 

-

 

RubberGum (horizontal joints)

 

 

TESTING FOR WATER LEAKS

 

LEAVE THE SHOWER 24 HOURS AFTER BUILD TO ALLOW SEALENT TO CURE AND ENSURE 

THE SHOWER IS AWAY FROM ITS FINAL POSITION TO ALLOW REAR VIEWING

 

Ensure all connections are tight and sealed including the waste, body jets and steam outlet (model 

dependent) on your shower. 

We also advise to run a thin bead of silicone around the control panel.

 

Switch on the overhead shower NOT the massage jets, remember these will fire water out at you and 

are not suitable for checking leaks as they would normally only operate when a person is in front of 

them. DO NOT AIM THE HAND SHOWER AT THE JOINTS OF YOUR SHOWER AS THIS DOES 

NOT FALL UNDER 

NORMAL EVERYDAY USE

”. 

Adjust the feet to ensure the  direction of the water 

flows towards to the waste to prevent puddling.

 

Just use COLD water setting as hot will make cabin misty and condensate thus the inspection 

becomes very difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal, hose, clip 

and jet by walking from one side and going around to the back and then to the other side finishing at 

the front. If you have a small leak (normally caused through insufficient sealer or air bubble on 

assembly, dry the area thoroughly and reseal.

 

Please remember the location of the water may not be exactly where the leak is as it could have run 

around to a low point. Never seal your inner fittings unless necessary, remember you will see this for 

the life of the shower! Again leave to cure and check. Once you are happy check the shower functions 
i.e. jets for back massage, foot massage and finally hand shower (model dependent) check your joints 

to these functions at the rear again. Never use the shower until 

all

 checks have been made and the 

installer is 100% happy in the knowledge no leaks are present. 

 

Important Note:

 

 

 

It is not uncommon due to temperature changes, 

 

glass seals fitted into the frame 

lower horizontal and sides can and do shrink leaving a small gap. This is normal to prevent rubbers 
perishing or opening later in your showers life. Check yours now, any slight gaps simply seal neatly 

with a thin bead of silicone. This will prevent chances of leakage both now or later in life. 

 

All good?

 

Now push your shower FROM THE BASE and NEVER THE GLASS OR FRAME into its final resting 

position.

 

Happy Showering! 

Summary of Contents for INS9000

Page 1: ...nts Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __________________________ To claim your full 5 year warranty register your shower within 90 days of delivery at www insigniarange co uk warrantyreg aspx Standard 12 month warranty applies if outside ...

Page 2: ...ical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Steam Generator Connections Sealing and Water Testing SUN Control Panel Instructions Help Book Information Spare Parts 3 5 6 7 8 10 11 26 27 28 31 32 ...

Page 3: ...any years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Very easy 2 Badges Easy 3 Badges Moderate 4 Badges Harder than average 5 Badges Professional skills requi...

Page 4: ...ED ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN YOURS AND OTHERS SAFETY IS PARAMOUNT NEVER ATTEMPT THIS YOURSELF REMEMBER These showers are designed to be free standing and movable from their location should you have the need to replace anyth...

Page 5: ...rician This product comes with 13 amp plug s fitted with an RCD unit We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current laws and IP directives 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Always use protection against electrical surge Your shower should be treated th...

Page 6: ...icone Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Hardware Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints A Steam Shower requires 3 x 1 Metre Braided Hose Not Supplied Not Supplied Not Supplied Supplied ...

Page 7: ...d fully how the unit is assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final fix What s In The Boxes Tray Box 1x Tray 1x Roof 2x Curved Rails Accessories Box Glass Room 2x Door seals 2x Glass door 2x fixed glass Backwalls...

Page 8: ...o replacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Description Quantity SP097 Door Handles 2 SP276 4 x Double wheels 4 SP276A Push Button Door Wheels 4 ST20 20mm Screws 8 ST12 12mm Screws 24 BN22 N6 SW9 22mm Screws Washers Hex Nut 10 PRC20 Securing Cl...

Page 9: ...er plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is free standing and is designed to be pulled away from the wall Th...

Page 10: ...www insigniarange com Last Modified 08 02 2018 10 ...

Page 11: ...ave a clear space remember when finished and in place you need access to check your build and able to pull the shower out for servicing or should you have the need to replace anything Take the shower tub and remove all the protective wrapping and fit the waste In the side of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is ...

Page 12: ...e which is for the hose going from the steam generator to the waste Connect two of the back panels as shown in the image Ensure that you insert the T Strips between the left and centre panel and run a bead of silicone in the T on either side red vertical line Secure into position using the B28 N10 BW12 bolts washers and hex nuts as shown in the image below at all four points Place on tray to align...

Page 13: ...www insigniarange com Last Modified 08 02 2018 13 Step 1 continued Take the third back panel and connect using the exact same process as the previous page ...

Page 14: ...at the top to allow the fitting of the roof so make sure you connect the frame with the cut out located at the top Step 3 RubberGum You can jump forward and do step 4 now if you wish and return here after to apply the RubberGum Apply RubberGum around the tray to seal the back panels to it Also apply around the curve to seal the framework to the tray as well You should have placed the three back pa...

Page 15: ...k panels shown on the diagram as red vertical lines If you opted to connect this framework prior to applying RubberGum then please return to step 3 and apply RubberGum Once aligned onto the RubberGum now you can go round the back of the shower and connect the back panels to the tray The holes are not pre made for this in the tray but they are in the back panels so you will need your drill DB6 B22 ...

Page 16: ...and lay them down gently Now attach the U shape rubber seal to one side of each panel and cut off any excess Step 5 continued Now push the front fixed glass into the frames in the direction as shown by the below arrows and then fix into place using the PRC20 securing clips and ST12 screws ...

Page 17: ...arange com Last Modified 08 02 2018 17 Step 6 Align the roof into position and connect using the nuts bolts and washers B22 N6 SW9 connect the back panels to the roof NOTE If a small gap exists silicone seal later ...

Page 18: ...nner curved rails with the wheels facing the outside of the glass Please note the push button wheels are for the bottom Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a tight fit Now grease the track to ensure a smooth and long lasting operation not supplied ...

Page 19: ...e outside of the door and secure by tightening the inner chrome knob to the protruding inner thread Magnetic Seals If not fitted Push the magnetic door seal on the handle side of the glass door ensuring this is tightly fitted Door Seals Place the rear door seals on the outer edge of each of the front glass panels as shown on the image on the left hand side ...

Page 20: ... to the back of the centre column fixing it from the rear with the plastic hex nut 3 Attach the chrome flexible hose to the water outlet with via small coupling end 4 Attach the other end sleeved to the hand shower and place in to the holder NOTE If you attach the wrong end of the hose to the hand shower it will not sit in the holder Please see your AMI system installation guide for further detail...

Page 21: ... into the rear hole as shown in the image Now from the inside of the shower re attach the chrome pepper pot end and tighten Monsoon Head Screw the threaded tube in to the top of the monsoon shower head and pass it up through the light diffuser and through the hole in the shower roof Secure in to position with the hex nut Next Attach the grey hose from your shower valve to the threaded tube using P...

Page 22: ...and Once this is done the lights simply push onto the fitting Start on one side with the light closest to the middle as shown below Follow the lights around and finish back where you started so you can compete the circuit Please Note When connecting the roof LED lights to the electric box only the male connection is needed leaving the female connection hidden away under the roof cover 2 Tighten Nu...

Page 23: ...top of the shower cabin Because of this we have a cover that simply slots over the top secured in place around the thread of the monsoon rain shower Please note this will be screwed into position once the monsoon head is connected Ensure you connect the Ozone prior to securing the light cover in position This has no bearing on the function of the shower itself It is purely for aesthetics purposes ...

Page 24: ...ater exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew fully as this will drop within the chrome knob this is found on the opposite side to the chrome pillar Once you have succeeded in loosening this you can now slide your faceplate to correspond to the d...

Page 25: ...signiarange com Last Modified 08 02 2018 25 Electric Box Connections Connect the cables below to the corresponding devices on the shower Roof Light Speaker Antenna Thermostatic probe 12V power Supply Speaker ...

Page 26: ... steam pod within your shower Make sure these are fitted in the correct position as they are on ly attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening Not supplied Drain Connect the grey rubber hose from the steam generators drain opening to the nozzle on the shower waste as shown in the below image ...

Page 27: ...rom one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal Please remember the location of the water may not be exactly where the leak is as it could have run around to a low point Never seal your inner fittings unless necessary remember...

Page 28: ...y activated Other buttons will remain functional whilst in this state of lock mode Button 5 Music Press once for FM Radio and press twice for Bluetooth For tuning radio stations or connecting Bluetooth please see the next page For volume control once on the radio or Bluetooth setting press Mode button 3 then use the left and right arrows to change the volume The volume is denoted by a number follo...

Page 29: ...Step 1 To tune your radio channels firstly press the music function button which looks like a musical note Tuning your radio channels Step 1 To connect a device via Bluetooth press the music function button twice which looks like a musical note the control panel will then show INS Step 2 Then once the radio is on press and hold the mode button until it starts scroll ing Step 3 Finally once the pan...

Page 30: ... contains many useful items such as is your parts warranty registered advice on cleaning servicing your shower cabin fault finding and many more items This is a MUST to read and not just HELP It saves time in nearly all cases avoiding contact with ourselves as most answers are there for a ready fix Simply visit www insigniarange co uk help aspx ...

Page 31: ... SP270 Chromotherapy Lighting SP039 Fan Model Dependent SP078 Ozone SP050 Seat Pad Part Code Part Description SP302 White insulated pipe x2 SP187 Drain Hose SP040 Steam generator electric box External Items Parts List Part Code Part Description INS9000 2 Roof INS9000 3 Column Blank INS9000 11 Top Bottom Door Rail INS9000 10 Bottom Door Rail INS9000 9 Top Door Rail INS9000 1 Tray INS9000RC Roof Cov...

Page 32: ...e used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered with ImageTraker Insignia is a registered trademark of Maclean International Ltd ...

Reviews: