background image

14

PROPERTY DAMAGE

n  

Regularly inspect the unit for any signs of leakage. 

If there are signs of water damage, immediately 

remove the unit from service.

n  

To avoid water damage from leakage, replace all 

cut, loose or split tubing

.

n  

A drain pan, plumbed to an appropriate drain must 

be used in those applications where any leakage 

could cause property damage. A leak detection 

device with water shutoff is recommended.

CLEANING THE FAUCET AND TANK

 Only use mild cleaners to clean the faucet and 

outside of the tank.

 Cleaners with acids, abrasives, alkaline or organic 

solvents will result in deterioration of the plastic 

components and void the warranty. 

SEASONAL STORAGE / DRAINAGE

Disconnect power from unit.

n  

Disconnect tubes from the tank.

n  

Water inside tank is 145°F (63°C). Allow water 

in tank to cool.

n  

Open T&P valve on tank.

n  

Unhook tank from wall.

n  

Hold tank upside down and drain water into  

the sink.

PERSONAL INJURY

n  

Regularly check for signs of corrosion by  

examining the appearance of the dispensed water.

n  

If there is any discoloration or rusty appearance, 

unplug and drain unit as described in the 

Seasonal Storage/Drainage section on this page 

of the manual

.

n  

If the water discoloration remains after draining 

and refilling unit, discontinue use and contact an 

authorized InSinkErator service agent.

Care & Use

ELECTRIC SHOCK HAZARD

To prevent electrical shock, disconnect power before servicing unit. Use only a GFCI outlet.

n  

Towel dry any water drippings from the tank area.

n  

Reinstall tank to the wall and reconnect the tubes.

n  

Ensure that the T&P valve is closed.

n  

Turn on cold water supply at valve, plug in power 

cord, then activate faucet for 2 minutes until 

water flows from the spout. There is a 5 minute 

startup delay before the heater will turn on. The 

heater will run through the startup process and 

will take approximately 10 additional minutes for 

the water to reach temperature.

RE-CONNECTING AFTER STORAGE

Summary of Contents for Instant Warm Handwash System

Page 1: ...tallation Care Use Manual www insinkerator com foodservice Please be certain that the person who installs or uses this appliance carefully reads and understands the Safety Instructions contained in th...

Page 2: ...when temperatures are expected to drop below 40 F 4 C see Seasonal Storage Drainage section Do not use a torch or other high temperature sources near system plastic fittings or plastic plumbing Do not...

Page 3: ...e replaced in order to avoid a hazard Do not connect to water supply exceeding 80 F 27 C Do not connect to the water supply if the water pressure exceeds 70 PSI IMPORTANT SAFETY INFORMATION WARNING in...

Page 4: ...of owner and or installer Reference the latest version of the Uniform Plumbing Code UPC for specific details and requirements IMPORTANT SAFETY INFORMATION NOTICE The maximum working pressure of 150 PS...

Page 5: ...standard dedicated 115 volt GFCI outlet DO NOT extend plumbing or electrical lines Figure 1 Typical Installation Shown Components In This Package Ensure the incoming water line is connected shutoff va...

Page 6: ...es 2 Screw Driver M2 5 Hex Key Discharge Pipe Water Supply Hose Tape Measure Level Basin Nut Wrench Thermometer Shutoff Valve Anchors SUPPLIES YOU MAY NEED SUPPLIES NEEDED Required Tools Materials Sin...

Page 7: ...mm These instructions are separated into main sections indicated by numbers and subsections indicated by capital letters The manual is setup this way to allow you to take a break at any point after co...

Page 8: ...ll spout into faucet base and tighten set screw to secure 2 1 1 1 1 3 2 Install threaded sleeve s into bottom of faucet A 2 2 2 After inserting sensor connection wire install sensor into faucet base T...

Page 9: ...l faucet rests on deck splash 1 5 2 From underneath or behind sink install washer s and large nut s onto threaded sleeve s Use an adjustable wrench to secure 2 2 7 3 1 Screws provided are for use in w...

Page 10: ...hose 2 9 Insert tubing into fitting from the faucet hose and press until it bottoms out Pull on connections to insure tubes are fully seated Tube should insert approximately 5 8 10 Connect sensor fro...

Page 11: ...xceeding 80 F 27 C PROPERTY DAMAGE Join remaining tube to cold water supply only NOTICE 12 Make sure the water hose is properly connected to the cold water source with valve 8 FINAL INSTALLATION 13 Tu...

Page 12: ...o prevent accidental or unauthorized temperature adjustment Wait a few minutes for tank to re heat and re check temperature 2 If needed turn temperature adjustment screw counterclockwise for hotter or...

Page 13: ...d place a hand in the desired sensor activation location Wait for 5 seconds until the red LED on the sensor turns off Test the new activation location by placing a hand in front of the sensor d the ca...

Page 14: ...pside down and drain water into the sink PERSONAL INJURY n Regularly check for signs of corrosion by examining the appearance of the dispensed water n If there is any discoloration or rusty appearance...

Page 15: ...h TMV is not adjusted to your needs Adjust TMV and re measure output water temperature as described in the Adjusting the Thermostat section on page 12 of this manual Undesired output stream Debris in...

Page 16: ...d warranty Only an authorized InSinkErator service representative may provide warranty service InSinkErator is not responsible for warranty claims arising from work performed on your InSinkErator Prod...

Reviews: