14
PROPERTY DAMAGE
n
Regularly inspect the unit for any signs of leakage.
If there are signs of water damage, immediately
remove the unit from service.
n
To avoid water damage from leakage, replace all
cut, loose or split tubing
.
n
A drain pan, plumbed to an appropriate drain must
be used in those applications where any leakage
could cause property damage. A leak detection
device with water shutoff is recommended.
CLEANING THE FAUCET AND TANK
n
Only use mild cleaners to clean the faucet and
outside of the tank.
n
Cleaners with acids, abrasives, alkaline or organic
solvents will result in deterioration of the plastic
components and void the warranty.
SEASONAL STORAGE / DRAINAGE
n
Disconnect power from unit.
n
Disconnect tubes from the tank.
n
Water inside tank is 145°F (63°C). Allow water
in tank to cool.
n
Open T&P valve on tank.
n
Unhook tank from wall.
n
Hold tank upside down and drain water into
the sink.
PERSONAL INJURY
n
Regularly check for signs of corrosion by
examining the appearance of the dispensed water.
n
If there is any discoloration or rusty appearance,
unplug and drain unit as described in the
Seasonal Storage/Drainage section on this page
of the manual
.
n
If the water discoloration remains after draining
and refilling unit, discontinue use and contact an
authorized InSinkErator service agent.
Care & Use
ELECTRIC SHOCK HAZARD
To prevent electrical shock, disconnect power before servicing unit. Use only a GFCI outlet.
n
Towel dry any water drippings from the tank area.
n
Reinstall tank to the wall and reconnect the tubes.
n
Ensure that the T&P valve is closed.
n
Turn on cold water supply at valve, plug in power
cord, then activate faucet for 2 minutes until
water flows from the spout. There is a 5 minute
startup delay before the heater will turn on. The
heater will run through the startup process and
will take approximately 10 additional minutes for
the water to reach temperature.
RE-CONNECTING AFTER STORAGE