background image

10

TROUBLESHOOTING

WHAT TO DO

Water and steam spits
forcefully from spout
without turning on the
faucet.

No warm water

• Water is boiling in storage tank.

May be normal during initial setup.

• The unit is unplugged.

• The electric outlet is inoperative.

• Lift faucet lever to release some water from 

the tank.

• Adjust water temperature down using dial on tank front.

Remember that at higher altitudes, water boils 
at lower temperatures.

• Make sure the unit is connected to a properly grounded 

electric outlet.

• Make sure the circuit breaker or fuses are 

functioning properly.

• Check that the outlet is not switched off.

Water is too hot 
or not warm enough

• Thermostat is not adjusted to 

your needs.

• Adjust the thermostat slowly, then lift faucet handle for 20

seconds to bring in fresh water to be heated at the new setting.
Allow 5-7 minutes for water to reach new temperature.

Water comes out the
vent instead of spout

• Outlet tube is blocked.

• Check that outlet tube is not kinked, twisted or pinched.

• Unscrew spout end piece and clean out any debris.

Water is dripping from 
the spout/vent
intermittently

• The expansion chamber isn’t draining

properly due to low water pressure.

• The spout is blocked.

• Unplug the unit. If the dripping doesn’t stop after a few

minutes, check the supply valve to ensure that is fully
open and there are no obstructions in the water line
reducing the pressure below 30 psi (

i.e., a poorly mounted

saddle valve, a clogged water filter, or a partially opened
shut-off valve).

• Unscrew spout end piece and clean out any debris.

Water is dripping 
from the spout/vent
constantly

• Debris in the water line may be 

in the faucet valve seat causing a 
slow water leak.

• Unscrew spout end piece and clean out any debris.

• Lift faucet lever 7-10 times to flush faucet & lines.

Divided stream

• Debris in the end piece.

• Unscrew spout end piece and clean out any debris.

PROBLEM

POSSIBLE CAUSE

Please read Troubleshooting Guide and/or visit 
www.insinkerator.com before calling AnswerLine

If you are still experiencing trouble call the AnswerLine

1-800-558-5700.

Summary of Contents for Ultra System

Page 1: ...do Uso Installation Sion Utilisation Owner s Manual The Emerson logo is a trademark and a service mark of Emerson Electric Co InSinkErator is a division of Emerson Electric Co 44062 0407 www insinkerator com Printed in USA 2007 InSinkErator ...

Page 2: ...required under the sink for the faucet s electrical power Q The wall outlet powering the tank must have electrical power supplied to it continuously Q This outlet must be fused and should not be controlled by the same wall switch that operates a food waste disposer unless you have a SinkTop Switch from InSinkErator Q If you suspect elevated levels of chlorine in your water it is recommended to use...

Page 3: ...used It should not be controlled by the same wall switch that operates a food waste disposer PREPARATION START HERE PROPER INSTALLATION SHOULD TAKE ABOUT 2 4 HOURS Q Identify locations for the faucet and tank Q Check to make sure there is proper clearance for faucet handle to be fully opened Q Check to make sure counter is not too thick Q Make sure there is a grounded electrical outlet under the s...

Page 4: ...e on the spot selected for installation use a pencil to mark locations for 2 hanging screws Property Damage Tank must be located within 16 of faucet and within 30 or less of a standard grounded outlet DO NOT extend plumbing or electrical lines 3 MOUNTING THE TANK Tank must be mounted level to ensure proper operation Mount tank vertically in an area that allows clearance on the underside of the tan...

Page 5: ...in serious injury or death from electrical shock 1 year warranty Covers all replacement parts and labor to correct defects in material or workmanship in the faucet system excluding the replaceable filter cartridge for the full warranty period from the date of installation in your home If warranty service is required during the warranty period contact an authorized InSinkErator service agent to rep...

Page 6: ...nt d 0 setting few ully e mounted ened 00 ...