156
For some RAID drivers, it needs to load several times.
b.
If it fails to create 2T partitions, check BIOS Advance -> CSM Configuration-> Boot option
filter, enable the UEFI option, and select UEFI mode to boot the system. It needs to enter
the CMD command line to change the HDD format to GPT, and then partitions larger than
2T can be created.
c.
If the C disk utilization is too large after system installation, open Computer Property->
Advanced System Property-> Advanced-> Performance-> Settings-> Change Virtual Memory,
turn down the virtual memory or allocate the virtual memory to other partitions.
d.
If above operations could not resolve the problem, please contact Inspur customer
service.
2)
Abnormal memory capacity
Description:
The memory capacity displayed in the OS and the physical memory capacity are
inconsistent.
Suggestions:
a.
Check the OS version, the supported memory capacity varies with the version of Windows
OS. Enter BIOS Setup to view the memory capacity, if the memory is identified completely,
the operating system may have limits to the memory capacity, e.g. Windows server 2008
x86 supports 4G memory at most.
b.
If the memory is not identified completely in BIOS Setup, confirm that the corresponding
slots have been installed with memories of correct type.
c.
If above operations could not resolve the problem, please contact Inspur customer service.
3)
Abnormal network
Description:
The network is disconnected, or the rate is lower than the actual rate of the
network port.
Suggestions:
a.
Check whether the network cable is connected well and whether the network LED flashes
normally, re-insert the network cable to test again.
b.
If the problem still exists, use a computer to connect with the server directly. If the direct
connection is normal, check whether the network cable or the switch port is normal.
c.
If the direct connection is abnormal, please visit Inspur website (http://www.inspur.com)
to download the latest NIC driver.
d.
If above operations could not resolve the problem, please contact Inspur customer service.
Summary of Contents for AGX-5
Page 1: ...Inspur Server User Manual NF5888M5 AGX 5 V1 1 ...
Page 18: ...12 shown below ...
Page 22: ...16 ...
Page 37: ...31 Cabling Note Please route the cables according to the purchased machine configuration ...
Page 46: ...40 Fig 2 11 Fig 2 12 Fig 2 13 ...
Page 113: ...BMC settings 107 ...
Page 116: ...110 ...
Page 118: ...112 One key collect log One key collect log ...
Page 123: ...BMC settings 117 ...
Page 139: ...BMC settings 133 ...
Page 142: ...136 ...
Page 144: ...138 ...
Page 149: ...BMC settings 143 ...