53
7.1.2
No Display
Symptoms:
After pressing the power button, the power LED on the power button changes from
orange to green, the system fans work normally, but there's no output on the
monitor.
Solutions:
1.
Check whether the monitor is powered up normally;
2.
If yes, but there is still no output on the monitor, check whether the monitor is
connected properly to the server's VGA port;
3.
If yes, but there is still no output on the monitor, please replace with another
monitor;
4.
If the problem still persists, maybe the VGA port is abnormal. Please log into
the BMC Web interface. Launch the BMC remote KVM (For detailed reference
document, see
Firmware Update and Configuration
) to see if KVM can be
displayed normally: If yes, maybe the VGA port on the motherboard is
abnormal, please contact Inspur Customer Service; if no, please record the
detailed warning information;
5.
If the instructions above do not resolve the problem, please call Inspur
Customer Service Hotline (1-844-860-0011/1-760-769-1847) or email to
, and inform us of the detailed warning information
and failure.
7.1.3
Abnormal LED on the Front Panel
Symptoms:
The status LED on the front panel illuminates red.
Solutions:
Identify the abnormal LED based on "
1.
If the system status LED illuminates red, check whether the server is under
normal operation: If yes, log into the BMC Web interface to view the BMC logs
(For detailed reference document, see
Firmware Update and Configuration
) to
check whether there are warnings. If yes, please record the detailed warning
information;
a.
If the power status LED is abnormal, please check if the PSU LEDs on the
rear panel are abnormal (amber or off): If the PSU LEDs are normal, please
log into the BMC Web interface to check the BMC logs (For detailed
reference document, see
Firmware Update and Configuration
) to see if
there are warnings. If yes, please record the detailed warning information;