BMC Settings
131
If sensor event type is generic, please refer to
Generic Event/Reading Type Code
table in
IPMI Specification, Version 2.0.
If sensor event type is sensor-specific, please refer to
Sensor Type Code
tables in IPMI
Specification, Version 2.0.
●
Assertion/De-assertion
Assertion and de-assertion indicators reveal the type of events this sensor generates.
9.8.2 CPU
Table 22 CPU Health State Monitored
State
Level
Related Model
Present
Info
SDR/SEL
Thermal Trip
Critical
SDR/SEL
Processor Hot
Critical
SDR/SEL
Catt Error
Critical
SDR/SEL
Error0
Warning
Blackbox
Error1
Warning
Blackbox
Error2
Critical
Blackbox
CPU VR Hot
Critical
Blackbox
PCH Thermal Trip
Critical
Blackbox
9.8.3 Memory
Table 23 Memory Health State Monitored
State
Level
Related Model
Mem Hot
Critical
Blackbox
Mem VR Hot
Critical
Blackbox
ECC
Warning
SDR/SEL
Uncorrectable ECC
Critical
SDR/SEL
9.8.4 HDD
Table 24 HDD Health State Monitored
State
Level
Related Model
Present
Info
SDR/SEL
Error
Critical
SDR/SEL
Rebuild
Warning
SDR/SEL