BMC Settings
159
smoothly without affecting the service.
Conditions that standby power switches to the main power:
1.
Main power supply is pulled out;
2.
Main power supply output voltage is low or no output;
3.
Main power supply temperature is too high, input loss, overcurrent, or overvoltage;
4.
System power as a percentage of main power supply rated power reaches the upper limit.
Figure 9-4
7
PSU Active Standby
9.21.3 Power Peak
Power peak is used to prevent many servers from being started at the same time when first
time A/C power is restored, which would cause heavy power loading.
●
Power peak can be enabled or disabled. Disabled by default.
●
When it is enabled, users can configure the maximum random time.
●
BMC will power on server with a random time delay within the time configured.
Click “Power and Fan -> Power Peak” to go to the configuration page.
Figure 9-4
8
Power Peak