4.5 Install the Access Panel
1.
Place the rear access panel on the server. Align the guide pins on both sides with the
corresponding guide slots on the chassis base.
2.
Push the rear access panel to the closed position and tighten the two screws clockwise.
3.
Open the hood latch, place the front access panel on the server, and align the guide pins
on both sides with the corresponding guide slots on the chassis base.
4.
Align the hole on the hood latch with the alignment pin on the top of the PCIE bracket and
push the hood latch to the closed position.
4.6 Remove the PCIE Riser Cage
CAUTION:
To prevent damage to the server or expansion boards, power down the server
and remove all AC power cords before removing or installing the PCIE riser cage.
1.
Power down the server.
2.
Extend the server from the rack.
3.
Remove the front access panel.
4.
Disconnect the cables (if any) from the PCIE Riser cage.
5.
Press the latch in the direction shown in the figure.