26
Step 3: Install the assembled heatsink module onto the CPU socket, and the position marked
by “1” should be aligned with the triangle mark on the CPU socket. Tighten the screws
according to the sequence of 1, 2, 3, 4.
Notes:
●
It is required to coat thermal grease evenly onto the contact position between CPU
heatsink and CPU.
●
During fixing CPU heatsink, it is required to fasten bolts according to the sequence
accordingly.
6.3 Memory Option
IMPORTANT:
This server does not support mixing DIMMs. Attempting to mix the DIMMs of different types
may cause the server stops running during initialization.
All DIMMs installed in the server must be the same type.
●
DIMM slot layout is as shown in the following figure: