25
Hardware Options Installation
4.
Connect the power cord to the power supply.
5.
Route the power cord through the power cord anchor or cable management arm.
6.
Reposition the cable management arm into the operating position.
7.
Connect the power cord to the power source.
8.
Verify that the corresponding power supply LED is green.
6.4 Air Baffle Option
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
1.
Power down the server.
2.
Extend the server from the rack.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the host surface to
cool before touching it.
Step 1: Remove the hard drive tray above the air baffle.
Step 2: Remove the front and rear air baffles vertically according to the direction of arrow in