NUMBER  OF 

FLASHES 
BETWEEN 
PAUSES 

MEANING 

ACTION 

1 Constant  

Water level sensor has scaled up 
at  normal level and  machine has 
filled to a higher level 

Clean Sensing Probes 

Operating  level  sensor  has  been 
detected  but  lower  level  sensor 
has not 

Clean Sensing Probes 

Overfill  level  sensor  has  been 
detected  but  other  sensors  have 
not 

Clean Sensing Probes 

Danger  level  sensor  has  been 
detected  and  machine  functions 
have been shut down 

Clean Sensing Probes 

Boiler has overheated 

Call Instanta service 
department 
Quoting the Serial Number 

Boiler  has  failed  to  fill  in  the 
allotted time. Possible causes: 

1. 

 

Water supply turned off. 

2. 

 

Water inlet valve has failed. 

3. 

 

Blockage in water inlet pipe. 

4. 

 

Pipe  connecting  inlet  valve  to 
boiler has become detached.  

Check water supply 
 
If in order call Instanta service 
department quoting the Serial 
Number 

The  temperature  sensor  has 
become  disconnected  or  the 
heating element(s) have failed.  

Call Instanta service 
department 
Quoting the Serial Number 

8  or  9 

Fault on temperature sensor. 

Call Instanta service 
department 
Quoting the Serial Number 

10 

Heating  element(s)  faulty  or  a 
system fault.   

Call Instanta service 
department 
Quoting the Serial Number 

11 

The  water  supply  has  been 
interrupted  and  the  level  has 
fallen  to  a  point  at  which  the 
heating  element(s)  could  be 
damaged. 

Check water supply 
 
If in order call Instanta service 
department quoting the Serial 
Number 

12 

The machine has over-boiled and 
the  level  has  fallen  to  a  point  at 
which  the  element(s)  could  be 
damaged.  

Call Instanta service 
department 
Quoting the Serial Number 

  
 
 
 

INSTANTA LIMITED, Canning Road, Southport, Merseyside PR9 7SN 

 

Tel: 01704 501114 

Fax: 01704 501115  

Summary of Contents for MOD18

Page 1: ...Titan Pro Bulk Water Boiler MOD18 INSTALLATION and USER INSTRUCTION MANUAL Serial Number __________ IB18 Issue 3 ...

Page 2: ...ive years of trouble free service provided that the instructions contained in this manual are followed Instanta products are energy efficient simple to operate and easy to service Installation is straightforward but it is recommended that this be carried out by a properly qualified fitter 2 0 ACCESSORIES The new boiler is supplied with the following components and should be verified before install...

Page 3: ...xt to the machine is often helpful in notifying users that the appliance contains and dispenses near boiling water During normal use of the boiler certain surfaces will become hot especially the draw off taps and swivelling dispense arms Care should be taken to avoid potential injury from burns and scalding whilst operating the appliance Scale formation within hot water appliances is problematic a...

Page 4: ...r machine has been supplied with a WRAS approved non toxic hose for connection to a suitable drinking water supply The fittings are BSP A 15mm stop valve should be fitted between the water supply and the hose so that the machine can be isolated The water supply must have a pressure not exceeding 7 0bar 96psi and no lower than 2bar 28psi If your water pressure exceeds 7bar a suitable pressure reduc...

Page 5: ...rcumstances it is absolutely not possible to direct the boiler overflow outlet to a permanent waste or drain then the mains water supply to the boiler should be isolated and the unit switched off whenever it is left unattended for long periods e g overnight 4 4 ELECTRICAL CONNECTION All electrical work must comply with all relevant wiring regulations and be carried out by a qualified electrician a...

Page 6: ...e factory set between 96 and 98 C has been reached the amber ready light will illuminate This takes approximately 10 minutes Upon reaching the correct temperature the boiler will call for more water The machine will not fill completely all at once but in short controlled bursts that are electronically controlled to obtain maximum output temperature and efficiency Note The heating elements remain o...

Page 7: ...losing mode handle will return to closed position on release 2 Lock open mode for filling larger containers handle will have to be manually returned to the closed position IMPORTANT Whilst the handle is in the locked open position the boiler must not be left unattended e WARNING Care should always be taken to avoid injury whilst operating this boiler as the water temperature is maintained at near ...

Page 8: ...m Height 892mm Depth 550mm Weight empty 52kg Weight full 175kg Machine construction Outer casing and tank constructed from combination of type 304 and 316 stainless steel All boilers have electronic control of the main functions This means that the temperature is controlled precisely within given parameters The circuit constantly monitors the operation of the machine and warns the user via the ser...

Page 9: ...anel can be opened Once complete REMEMBER to close the drain tap Ensure all traces of de scaler are removed before using the boiler again Flush tank with copious amounts of clean cold water Examine the water level sensors for scale build up clean thoroughly as necessary using a non metallic scourer When de scaling is complete replace internal tank baffle plates tank lid and main outer lid Rather t...

Page 10: ...ler has become detached Check water supply If in order call Instanta service department quoting the Serial Number 7 The temperature sensor has become disconnected or the heating element s have failed Call Instanta service department Quoting the Serial Number 8 or 9 Fault on temperature sensor Call Instanta service department Quoting the Serial Number 10 Heating element s faulty or a system fault C...

Reviews: