NUMBER OF
FLASHES
BETWEEN
PAUSES
MEANING
ACTION
1 Constant
Water level sensor has scaled up
at normal level and machine has
filled to a higher level
Clean Sensing Probes
2
Operating level sensor has been
detected but lower level sensor
has not
Clean Sensing Probes
3
Overfill level sensor has been
detected but other sensors have
not
Clean Sensing Probes
4
Danger level sensor has been
detected and machine functions
have been shut down
Clean Sensing Probes
5
Boiler has overheated
Call Instanta service
department
Quoting the Serial Number
6
Boiler has failed to fill in the
allotted time. Possible causes:
1.
Water supply turned off.
2.
Water inlet valve has failed.
3.
Blockage in water inlet pipe.
4.
Pipe connecting inlet valve to
boiler has become detached.
Check water supply
If in order call Instanta service
department quoting the Serial
Number
7
The temperature sensor has
become disconnected or the
heating element(s) have failed.
Call Instanta service
department
Quoting the Serial Number
8 or 9
Fault on temperature sensor.
Call Instanta service
department
Quoting the Serial Number
10
Heating element(s) faulty or a
system fault.
Call Instanta service
department
Quoting the Serial Number
11
The water supply has been
interrupted and the level has
fallen to a point at which the
heating element(s) could be
damaged.
Check water supply
If in order call Instanta service
department quoting the Serial
Number
12
The machine has over-boiled and
the level has fallen to a point at
which the element(s) could be
damaged.
Call Instanta service
department
Quoting the Serial Number