background image

 

3.0  WARNINGS AND PRECAUTIONS 

 

Please read the following carefully before commencing work on this equipment. 
 
A competent  installation engineer, in accordance with the installation instructions of 
this  appliance  and  all  relevant  local  and  national  standards  including  the  following 
must install this appliance: 
 

  Health and Safety at Work Acts 

  IEE regulations 

  Local and National Building Regulations 

  BS Codes of practice 

  Water Supply Regulations   

 
Your new water boiler is designed to provide a constant source of near boiling water 
for the preparation of hot drinks. 

THIS IS VERY HOT

  

 
All  personnel  must  be  provided  with  sufficient  and  appropriate  training  in  the  safe 
use of this appliance. 
 
In line with Health & Safety requirements we recommend that a risk assessment be 
carried out after the boiler has been installed. 
 
A warning notice displayed next to the machine is often helpful in notifying users that 
the appliance contains and dispenses near-boiling water. 
 
During normal use of the boiler, certain surfaces will become hot (especially the draw 
off taps and swivelling dispense arms). Care should be taken to avoid potential injury 
from burns and scalding whilst operating the appliance. 
 
Scale formation within hot water appliances is problematic and more so in hard water 
areas. Damage to the appliance caused by excessive scale build-up may invalidate 
the warranty 

– see notes on de-scaling. 

 
Drawings, parts list, circuit/wiring diagrams are the sole property of Instanta Limited 
and must not be reproduced without their consent. 
 

 

This appliance is not intended for use by persons (Including Children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised to ensure they do 
not play with the appliance 

 
 
 
 

Summary of Contents for MOD18

Page 1: ...Titan Pro Bulk Water Boiler MOD18 INSTALLATION and USER INSTRUCTION MANUAL Serial Number __________ IB18 Issue 3 ...

Page 2: ...ive years of trouble free service provided that the instructions contained in this manual are followed Instanta products are energy efficient simple to operate and easy to service Installation is straightforward but it is recommended that this be carried out by a properly qualified fitter 2 0 ACCESSORIES The new boiler is supplied with the following components and should be verified before install...

Page 3: ...xt to the machine is often helpful in notifying users that the appliance contains and dispenses near boiling water During normal use of the boiler certain surfaces will become hot especially the draw off taps and swivelling dispense arms Care should be taken to avoid potential injury from burns and scalding whilst operating the appliance Scale formation within hot water appliances is problematic a...

Page 4: ...r machine has been supplied with a WRAS approved non toxic hose for connection to a suitable drinking water supply The fittings are BSP A 15mm stop valve should be fitted between the water supply and the hose so that the machine can be isolated The water supply must have a pressure not exceeding 7 0bar 96psi and no lower than 2bar 28psi If your water pressure exceeds 7bar a suitable pressure reduc...

Page 5: ...rcumstances it is absolutely not possible to direct the boiler overflow outlet to a permanent waste or drain then the mains water supply to the boiler should be isolated and the unit switched off whenever it is left unattended for long periods e g overnight 4 4 ELECTRICAL CONNECTION All electrical work must comply with all relevant wiring regulations and be carried out by a qualified electrician a...

Page 6: ...e factory set between 96 and 98 C has been reached the amber ready light will illuminate This takes approximately 10 minutes Upon reaching the correct temperature the boiler will call for more water The machine will not fill completely all at once but in short controlled bursts that are electronically controlled to obtain maximum output temperature and efficiency Note The heating elements remain o...

Page 7: ...losing mode handle will return to closed position on release 2 Lock open mode for filling larger containers handle will have to be manually returned to the closed position IMPORTANT Whilst the handle is in the locked open position the boiler must not be left unattended e WARNING Care should always be taken to avoid injury whilst operating this boiler as the water temperature is maintained at near ...

Page 8: ...m Height 892mm Depth 550mm Weight empty 52kg Weight full 175kg Machine construction Outer casing and tank constructed from combination of type 304 and 316 stainless steel All boilers have electronic control of the main functions This means that the temperature is controlled precisely within given parameters The circuit constantly monitors the operation of the machine and warns the user via the ser...

Page 9: ...anel can be opened Once complete REMEMBER to close the drain tap Ensure all traces of de scaler are removed before using the boiler again Flush tank with copious amounts of clean cold water Examine the water level sensors for scale build up clean thoroughly as necessary using a non metallic scourer When de scaling is complete replace internal tank baffle plates tank lid and main outer lid Rather t...

Page 10: ...ler has become detached Check water supply If in order call Instanta service department quoting the Serial Number 7 The temperature sensor has become disconnected or the heating element s have failed Call Instanta service department Quoting the Serial Number 8 or 9 Fault on temperature sensor Call Instanta service department Quoting the Serial Number 10 Heating element s faulty or a system fault C...