3.3.1. Soft Surface Installations
Always install and use the ground spikes provided with the standard transducer. For the best
coupling, bury the standard transducer.
a. Using the Ground Spikes
Screw the three ground spikes into the bottom of the standard transducer and tighten. Point the
arrow located on the top of the standard transducer in the direction of the event. Press on the top
of the standard transducer to push the spikes fully into the ground. Check the standard transducer
to ensure it is securely in place and level. Press the
Test
key to run Sensorcheck.
Figure 3.2 Installing the Standard
Figure 3.3 Final Installation with
Transducer using the Ground Spikes.
Ground Spikes Pushed Fully into the
Ground.
b. Burying the Standard Transducer
You can bury the standard transducer to couple it to the ground and prevent movement. The
ground must be hard and compact with no loose material between the standard transducer and the
compact ground material. Dig a hole from four inches (10 cm) to six inches (15 cm) deep. Attach
the ground spikes to the standard transducer. Position the standard transducer in the hole with the
arrow pointing toward the event. Press the ground spikes fully into the ground. Level the standard
transducer. Compact the material around the standard transducer while back filling to securely
couple to the surrounding ground material. Press the
Test
key to check your sensors.
Summary of Contents for Blastmate III
Page 1: ......
Page 6: ...iv BlastMate III Operator Manual Notes ...
Page 20: ...Chapter 2 2 6 BlastMate III Operator Manual Notes ...
Page 50: ......
Page 74: ...Chapter 6 6 6 BlastMate III Operator Manual Notes ...
Page 77: ...Appendix BlastMate III Operator Manual A 1 Appendix ...
Page 78: ...Appendix A 2 BlastMate III Operator Manual ...
Page 84: ...Appendix A 8 BlastMate III Operator Manual Notes ...
Page 90: ...Index I 6 BlastMate III Operator Manual Notes ...