Chapter 3
3–4
BlastMate III Operator Manual
Figure 3.4 Burying the Standard
Figure 3.5 Fill In and Pack the Material
Transducer. around
the
Standard Transducer.
3.3.2. Hard Surface Installations
For hard surface installations, such as rock, concrete or solid ice, the preferred installation method
bolts the standard transducer to the surface. A second method, for very low level velocities only,
uses a sandbag placed over the standard transducer.
a. Bolting the Standard Transducer
A standard transducer may be bolted to a surface alone or with the aid of the optional leveling
plate. Position the standard transducer with leveling plate, if attached, on the surface and mark the
position of the mounting bolt. Use a 3/8 inch (9.5 mm) bolt or threaded rod. Mount the bolt
according to the manufacturer’s instructions. Slide the standard transducer, and leveling plate,
over the bolt. Slide a 3/8 inch (9.5 mm) washer and a 3/8 inch (9.5 mm) lock washer over the bolt.
If using the leveling plate, level the standard transducer using the leveling feet and integrated
bubble level. Tighten the retaining nut to finish the installation. Press the
Test
key to check your
sensors using Sensorcheck.
Summary of Contents for Blastmate III
Page 1: ......
Page 6: ...iv BlastMate III Operator Manual Notes ...
Page 20: ...Chapter 2 2 6 BlastMate III Operator Manual Notes ...
Page 50: ......
Page 74: ...Chapter 6 6 6 BlastMate III Operator Manual Notes ...
Page 77: ...Appendix BlastMate III Operator Manual A 1 Appendix ...
Page 78: ...Appendix A 2 BlastMate III Operator Manual ...
Page 84: ...Appendix A 8 BlastMate III Operator Manual Notes ...
Page 90: ...Index I 6 BlastMate III Operator Manual Notes ...