Compliance Module
BlastMate III Operator Manual
3–15
Use the
Right Arrow
to move the cursor between hours and minutes, and the
Up Arrow
to
change the time, then press
Enter
to save your changes.
c. Sensorcheck
(Compliance Module Only)
This setting chooses when to automatically run Sensorcheck to test the monitor and its sensors.
You can run Sensorcheck manually by pressing the
Test
key. You can choose not to run
Sensorcheck, to run Sensorcheck after recording each event, or only once before monitoring
starts. If you choose Disabled, Sensorcheck does not run and the sensors are not checked. If you
choose After Each Event, Sensorcheck runs after recording each event. Results are saved with
each event and appear on the monitor display. If you choose Before Monitoring, Sensorcheck runs
once before monitoring starts, when you enter the monitor mode. The results of this single
Sensorcheck appear with each event recorded during the monitoring session. This reduces
processing time, by not having to run Sensorcheck for each event, and speeds up recording
especially when using the continuous record mode.
To set when to run Sensorcheck, press the Setups
Special
key when the Main Window is
displayed. Press the
Enter
key to scroll through the windows until the Sensorcheck: Window
appears. Press the
Up
or
Down Arrow
key to display the Disabled, After Each Event, or Before
Monitoring choices. Press the
Enter
key to select a choice when it appears on the BlastMate III
display.
d. Measurement System
(Compliance Module Only)
The BlastMate III uses the Metric or Imperial measurement system.
To choose either Metric or Imperial units, press the Setups
Special
key when the Main Window is
displayed. Press the
Enter
key repeatedly to scroll through the windows until the Measurement
System: Window appears. Press the
Up
or
Down Arrow
key to display the Imperial or Metric
choices. Press the
Enter
key to select a choice when it appears on the BlastMate III display.
e. Basic Channels
(Compliance Module Only)
You can operate four and eight channel monitors with all recording channels on or you can turn
off either the geophone or microphone recording channels. On eight channel monitors, choosing
to turn off either the geophone or microphone channels turns off all geophone channels (channels
1, 2, 3, and 5, 6, 7) or both microphones (channels 4 or 8). Also, all channels can be turned off
except one or two geophone channels.
You may, for example, turn off the microphone if your are monitoring inside a building where the
microphone is not applicable. This reduces the amount of memory required to save and store a
single event and therefore increases the overall number of events the BlastMate III can record and
store.
To turn basic channels on or off, press the Setups
Special
key when the Main Window is
displayed. Press the
Enter
key repeatedly to scroll through the windows until the Basic Channels:
Window appears. To monitor with only one or two geophone channels, choose the Geophone
Channel 1 or Geophone Channels 2 option. Choose 4 Channels ON on four channel monitors or 8
Channels ON on eight channel monitors to disable this feature. Another Basic Channels window
appears.
On eight channel monitors, press the
Up
or
Down
Arrow
keys to select either four or eight
recording channels. Press the
Enter
key. Press the
Up
or
Down
Arrow
key to display the choices.
Choose the All Channels On setting to record events with all the geophone and the microphone
channels on. Choose the Geo Channels OFF setting to record events without recording
information from the geophone channels. Choose the Mic Channel OFF setting to record events
Summary of Contents for Blastmate III
Page 1: ......
Page 6: ...iv BlastMate III Operator Manual Notes ...
Page 20: ...Chapter 2 2 6 BlastMate III Operator Manual Notes ...
Page 50: ......
Page 74: ...Chapter 6 6 6 BlastMate III Operator Manual Notes ...
Page 77: ...Appendix BlastMate III Operator Manual A 1 Appendix ...
Page 78: ...Appendix A 2 BlastMate III Operator Manual ...
Page 84: ...Appendix A 8 BlastMate III Operator Manual Notes ...
Page 90: ...Index I 6 BlastMate III Operator Manual Notes ...